Endress+Hauser Proline Promass Q 500 Coriolis flowmeter
Endress+Hauser 8Q5B - Flow measurement - Power Supply: DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area); Measuring range: 0 to 2 400 000 kg/h (0 to 88183.
In our catalog, the 8Q5B from Endress+Hauser is listed under the Flow measurement category. The manufacturer's published data for this part number specifies Power Supply: DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) and Measuring range: 0 to 2 400 000 kg/h (0 to 88183 lb/min).
IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure
The specification set recorded for this part number covers Measuring principle: Coriolis; Nominal diameter range: DN 25 to 250(1 to 10"); Product safety: CE, C-tick, EAC marking; Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC; Material certificates: 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK; Max. process pressure: PN 100, Class 600, 63K; Ambient temperature range: Standard: - 4 to +60 °C (–4 to +140 °F) Option:–60 to +60 °C (–76 to +140 °F); Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat; Inputs: Status input 4-20 mA input; Hygienic approvals and certificates: 3-A, EHEDG, cGMP; Pressure approvals and certificates: PED, CRN, AD 2000; Marine approvals and certificates: LR approval, DNV approval, ABS approval, BV approval, CCS approval. The complete technical table is shown in the Specifications tab on this page.
| Ambient temperature range | Standard: - 4 to +60 °C (–4 to +140 °F) Option:–60 to +60 °C (–76 to +140 °F) |
|---|---|
| Degree of protection | IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
| Inputs | Status input 4-20 mA input |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
| Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.25 % Density (liquid): +/-0.2 kg/m³ (standard), +/-0.1 kg/m³ (option) |
| Max. process pressure | PN 100, Class 600, 63K |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Measuring principle | Coriolis |
| Measuring range | 0 to 2 400 000 kg/h (0 to 88183 lb/min) |
| Medium temperature range | Standard: –50 to +205°C (–58 to +401 °F) Option: –196 to +150 °C (–321 to +302 °F) |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids) OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids) NTEP (Liquids other than water, Cryogenic liquids) |
| Nominal diameter range | DN 25 to 250(1 to 10") |
| Other approvals and certificates | CE, C-tick, EAC marking Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids) OIML R117 (Liquids other than water, Liquified gases, Cryo |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Power Supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Product headline | Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow and density. Highest measurement performance for custody transfer, density and under tough process conditions. |
| Product safety | CE, C-tick, EAC marking |
| Sensor features | Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point. |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Wetted materials | Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications Connection: 1.4404 (316/316L) |
Frequently Asked Questions
How do I get pricing for 8Q5B?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 8Q5B?
8Q5B is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 8Q5B?
Key specifications include Ambient temperature range: Standard: - 4 to +60 °C (–4 to +140 °F) Option:–60 to +60 °C (–76 to +140 °F); Degree of protection: IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure; Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA; Display/Operation: 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible. The full specification table on this page lists every published attribute for this part.
How quickly can 8Q5B ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Proline Promass Q 300 Coriolis flowmeter
Endress+Hauser Endress+Hauser Proline Promass S 100 Coriolis flowmeter
Endress+Hauser Endress+Hauser Proline Promass P 500 Coriolis flowmeter
Endress+Hauser Endress+Hauser Proline Promass S 300 Coriolis flowmeter
Endress+Hauser Endress+Hauser Proline Promass S 500 Coriolis flowmeter
Endress+Hauser