Endress+Hauser Proline Promass P 300 Coriolis flowmeter

Brand: Endress+Hauser SKU: 8P3B Mfr Part #: 8P3B
Ships Same Day* Worldwide Shipping

Endress+Hauser 8P3B - Flow measurement - Degree of protection: IP66/67, type 4X enclosure IP69; Power Supply: DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area); Measuring range: 0.

In our catalog, the 8P3B from Endress+Hauser is listed under the Flow measurement category. The manufacturer's published data for this part number specifies Degree of protection: IP66/67, type 4X enclosure IP69 and Power Supply: DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area).

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

The specification set recorded for this part number covers Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min); Measuring principle: Coriolis; Nominal diameter range: DN 8 to 50 (⅜ to 2"); Product safety: CE, C-tick, EAC marking; Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC; Material certificates: 3.1 material; Wetted materials: Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L); Max. process pressure: PN 40, Class 150, 20K; Ambient temperature range: Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F); Sensor housing material: 1.4301 (304), corrosion resistant; Transmitter housing material: AlSi10Mg, coated; stainless steel for hygienic transmitter design; Inputs: Status input 4-20 mA input. The complete technical table is shown in the Specifications tab on this page.

Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F)
Degree of protection IP66/67, type 4X enclosure IP69
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Display/Operation 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available"
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Hygienic approvals and certificates 3-A, EHEDG, ASME BPE, ISPE, cGMP
Inputs Status input 4-20 mA input
Material certificates 3.1 material
Max. measurement error Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Density (liquid): ±0.0005 g/cm³
Max. process pressure PN 40, Class 150, 20K
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Measuring principle Coriolis
Measuring range 0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature range Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F)
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Nominal diameter range DN 8 to 50 (⅜ to 2")
Outputs 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
Power Supply DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Pressure approvals and certificates PED, CRN
Product headline Specialist for life sciences with a compact, easily accessible transmitter. Dedicated to applications under sterile conditions in the life sciences industry.
Product safety CE, C-tick, EAC marking
Sensor features Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP.
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Transmitter housing material AlSi10Mg, coated; stainless steel for hygienic transmitter design
Wetted materials Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L)

Frequently Asked Questions

How do I get pricing for 8P3B?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 8P3B?

8P3B is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 8P3B?

Key specifications include Ambient temperature range: Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F); Degree of protection: IP66/67, type 4X enclosure IP69; Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA; Display/Operation: 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available". The full specification table on this page lists every published attribute for this part.

How quickly can 8P3B ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products