Endress+Hauser Proline Promass S 500 Coriolis flowmeter

Brand: Endress+Hauser SKU: 8S5B Mfr Part #: 8S5B
Ships Same Day* Worldwide Shipping

Endress+Hauser 8S5B - Flow measurement - Power Supply: DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area); Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min).

Endress+Hauser 8S5B is a Flow measurement catalog item from Endress+Hauser. The manufacturer's published data for this part number specifies Power Supply: DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) and Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min).

Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

Key manufacturer data on file for this item includes Measuring principle: Coriolis; Nominal diameter range: DN 8 to 50 (⅜ to 2"); Product safety: CE, C-tick, EAC marking; Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC; Material certificates: 3.1 material; Wetted materials: Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L); Max. process pressure: PN 40, Class 150, 20K; Medium temperature range: –50 to +150 °C (–58 to +302 °F); Ambient temperature range: Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F); Transmitter housing material: AlSi10Mg, coated; Polycarbonat; Inputs: Status input 4-20 mA input; Hygienic approvals and certificates: 3-A, EHEDG, cGMP. See the Specifications tab on this page for the full technical table.

Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F)
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Display/Operation 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Hygienic approvals and certificates 3-A, EHEDG, cGMP
Inputs Status input 4-20 mA input
Material certificates 3.1 material
Max. measurement error Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Density (liquid): ±0.0005 g/cm³
Max. process pressure PN 40, Class 150, 20K
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Measuring principle Coriolis
Measuring range 0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Nominal diameter range DN 8 to 50 (⅜ to 2")
Outputs 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
Power Supply DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Pressure approvals and certificates PED, CRN
Product headline Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os. Dedicated to applications requiring optimal cleanability under hygienic conditions.
Product safety CE, C-tick, EAC marking
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Sensor housing material 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Transmitter housing material AlSi10Mg, coated; Polycarbonat
Wetted materials Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L)

Frequently Asked Questions

How do I get pricing for 8S5B?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 8S5B?

8S5B is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 8S5B?

Key specifications include Ambient temperature range: Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F); Degree of protection: Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure; Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA; Display/Operation: 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible. The full specification table on this page lists every published attribute for this part.

How quickly can 8S5B ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products