IFM LDL100 - Conductive conductivity sensor - Material: stainless steel (1.4404 / 316L); PEEK; PEI; FKM; Weight: 270.5; Storage Temperature: -40...85.
The IFM LDL100 is part of the Conductive conductivity sensor range in our industrial catalog. The manufacturer's published data for this part number specifies Material: stainless steel (1.4404 / 316L); PEEK; PEI; FKM and Weight: 270.5.
Digital meets analog: integrating modern IO-Link sensors the analog way. The EIO104 allows you to realize two analog signals from intelligent IO-Link sensors with several process values.
Key manufacturer data on file for this item includes Storage Temperature: -40...85; Ambient temperature: -40...60; Connector: 1 x M12 (EN 61067-2-101); coding: A; Contacts: 4, gold-plated; Protection class: III; Output signal: analog signal; IO-Link; Product type: Conductive conductivity sensor; Accuracy: 20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K; Response time: < 2; (T09; Damping = 0); Communication interface: IO-Link; Measuring range: 100...15000; Operating voltage: 18...30 DC; Current consumption: < 60. The complete technical table is shown in the Specifications tab on this page.
| Accuracy | 20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K |
|---|---|
| Accuracy (in the measuring range) | 10 % MW ± 25 µS/cm |
| Ambient temperature | -40...60 |
| Analog current output | 4...20 |
| Cannot be used for | See the operating instructions, chapter "Function and features". |
| Communication interface | IO-Link |
| Connector | 1 x M12 (EN 61067-2-101); coding: A; Contacts: 4, gold-plated |
| Current consumption | < 60 |
| Drift | 0,2 %/K MW ± 25 µS/cm |
| IO-Link revision | 1.1 |
| Key Features | Reduce inaccuracies associated with a time-based cleaning process; Improve process performance with flexible measurement points; Compact, high-quality sensor design prevents failures and unplanned downtime |
| Long term stability | 1 % MW ± 25 µS/cm |
| Material | stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
| Materials (wetted parts) | PEEK; stainless steel (1.4404 / 316L) |
| Max. load | 500 |
| Measuring principle | konduktiv |
| Measuring range | 100...15000 |
| Media | Conductive liquids |
| Medium temperature | -25...100; (< 1 h: 150) |
| Min. process cycle time | 6.4 |
| MTTF | 172 |
| Notes | Digital meets analog: integrating modern IO-Link sensors the analog way. The EIO104 allows you to realize two analog signals from intelligent IO-Link sensors with several process values. |
| Number of analog outputs | 1 |
| Number of inputs and outputs | Number of analog outputs: 1 |
| Operating voltage | 18...30 DC |
| Output function | analog output scalable; selectable conductivity / temperature |
| Output signal | analog signal; IO-Link |
| Pack quantity | 1 pcs. |
| Power-on delay time | 2 |
| Process Connection | threaded connection G 1/2 external thread sealing cone |
| Process data analog | 1 |
| Product type | Conductive conductivity sensor |
| Protection | IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68) |
| Protection class | III |
| Repeatability | 5 % MW ± 25 µS/cm |
| Required master port class | A |
| Resolution | 1 |
| Response time | < 2; (T09; Damping = 0) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 |
| SIO mode | no |
| Special Feature | gold-plated contacts |
| Specification Summary | Conductive conductivity sensor; analog output scalable; selectable conductivity / temperature; analog; DC; M12 Connector; IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68); Ambient temperature -40...60 °C; Pressure rating 16 bar; G 1/2 external thread sealing cone; M12 Connector |
| Storage Temperature | -40...85 |
| Surface characteristics Ra/Rz of the wetted parts | Ra ≤ 0.8 µm |
| Total number of outputs | 1 |
| Transmission type | COM2 (38,4 kBaud) |
| Vacuum resistance | -1000 |
| Weight | 270.5 |
Frequently Asked Questions
How do I get pricing for LDL100?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the LDL100?
LDL100 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of LDL100?
Key specifications include Accuracy: 20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K; Accuracy (in the measuring range): 10 % MW ± 25 µS/cm; Ambient temperature: -40...60; Analog current output: 4...20. The full specification table on this page lists every published attribute for this part.
How quickly can LDL100 ship?
In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Industrial & MRO Parts