Endress+Hauser iTHERM MultiSens Flex TMS02Multipoint thermometer
Endress+Hauser TMS02 - Temperature - Accuracy: class 2 acc. to IEC 60584 ASTM E230 and ANSI MC 96.1 IEC/Class A IEC/Class AA; Response time: depending on configuration: TC: t50 = 2 s t90 = 5 s RTD: t50.
The Endress+Hauser TMS02 is part of the Temperature range in our industrial catalog. The manufacturer's published data for this part number specifies Accuracy: class 2 acc. to IEC 60584 ASTM E230 and ANSI MC 96.1 IEC/Class A IEC/Class AA and Response time: depending on configuration: TC: t50 = 2 s t90 = 5 s RTD: t50 = 0,8s t90 = 2s.
flange: 2" ASME/ANSI B16.5 150 ...600 3" ASME/ANSI B16.5 150 ..600 4" ASME/ANSI B16.5 150 ...600 6" ASME/ANSI B16.5 150 ...600 8" ASME/ANSI B16.5 150 ...600 DN80 EN/DIN 1092.1 PN10 ...PN100 DN100 EN/DIN 1092.1 PN10 ...PN100 DN125 EN/DIN 1092.1 PN10 ...PN100 DN150 EN/DIN 1092.1 PN10 ...PN100 DN200 EN/DIN 1092.1 PN10 ...PN100
Published specifications for this part include Measuring principle: Resistance Temperature Detector; Certification: SIL (transmitter only); Outer diameter protection tube / Insert: 6,0 mm (0,24'') 8,0 mm (0,31") 10,29 mm (1/8"); Max. immersion length on request: up to 30.000,00 mm (1181''); Material protection tube/ thermowell: 1.4401 (316) 1.4435 (316L) 1.4541 (321) 1.4550 (347) Alloy 600 (2.4816); Tip shape: straight reinforced easy-fix; Max. process pressure (static): at 20 °C: 200 bar (2900 psi); Integration head transmitter: yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS); Ex - approvals: ATEX IECEx UL FM CSA NEPSI CCC Ex ia. The complete technical table is shown in the Specifications tab on this page.
| Accuracy | class 2 acc. to IEC 60584 ASTM E230 and ANSI MC 96.1 IEC/Class A IEC/Class AA |
|---|---|
| Certification | SIL (transmitter only) |
| Characteristic / Application | metric style easy-to-use suitable for hazardous areas flanged process connection light chemical processes 3D sensors distributions modular design replaceable sensors during shutdown diagnostic chamber |
| Ex - approvals | ATEX IECEx UL FM CSA NEPSI CCC Ex ia |
| Insert / probe | mineral insulated (MI), flexible mineral insulated (MI), flexible, with its own thermowell |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Material protection tube/ thermowell | 1.4401 (316) 1.4435 (316L) 1.4541 (321) 1.4550 (347) Alloy 600 (2.4816) |
| Max. immersion length on request | up to 30.000,00 mm (1181'') |
| Max. process pressure (static) | at 20 °C: 200 bar (2900 psi) |
| Measuring principle | Resistance Temperature Detector |
| Operating temperature range | Type K: max. 1.150 °C (max. 2.102 °F) Type J: max. 720 °C (max. 1.328 °F) Type N: max. 1.100 °C (max. 2.012 °F) Pt100 WW; 3mm; 316L; -200...600oC Pt100 WW; 6mm; 316L; -200...600oC Pt100 TF; 3mm; 316L; -50…400oC Pt100 TF; 6mm; 316L; -50…400oC Pt100 StrongSens; 6mm; 316L; -50…500oC |
| Outer diameter protection tube / Insert | 6,0 mm (0,24'') 8,0 mm (0,31") 10,29 mm (1/8") |
| Process Connection | flange: 2" ASME/ANSI B16.5 150 ...600 3" ASME/ANSI B16.5 150 ..600 4" ASME/ANSI B16.5 150 ...600 6" ASME/ANSI B16.5 150 ...600 8" ASME/ANSI B16.5 150 ...600 DN80 EN/DIN 1092.1 PN10 ...PN100 DN100 EN/DIN 1092.1 PN10 ...PN100 DN125 EN/DIN 1092.1 PN10 ...PN100 DN150 EN/DIN 1092.1 PN10 ...PN100 DN200 EN/DIN 1092.1 PN10 ...PN100 |
| Response time | depending on configuration: TC: t50 = 2 s t90 = 5 s RTD: t50 = 0,8s t90 = 2s |
| Thermowell / protection tube | without (for direct contact sensors type) with (for replaceable sensors) with (for increased mechanical protection) Multi-thermowells, each one dedicated to a sensor |
| Tip shape | straight reinforced easy-fix |
Frequently Asked Questions
How do I get pricing for TMS02?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the TMS02?
TMS02 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of TMS02?
Key specifications include Accuracy: class 2 acc. to IEC 60584 ASTM E230 and ANSI MC 96.1 IEC/Class A IEC/Class AA; Certification: SIL (transmitter only); Characteristic / Application: metric style easy-to-use suitable for hazardous areas flanged process connection light chemical processes 3D sensors distributions modular design replaceable sensors during shutdown diagnostic chamber; Ex - approvals: ATEX IECEx UL FM CSA NEPSI CCC Ex ia. The full specification table on this page lists every published attribute for this part.
How quickly can TMS02 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser iTHERM MultiSens Flex TMS01Multipoint thermometer
Endress+Hauser Endress+Hauser iTHERM MultiSens Linear TMS11 Multipoint thermometer
Endress+Hauser Endress+Hauser TMR35Compact thermometer
Endress+Hauser Endress+Hauser iTHERM MultiSens Linear TMS12 Multipoint thermometer
Endress+Hauser Endress+Hauser TMR31Compact thermometer
Endress+Hauser
Industrial & MRO Parts