Endress+Hauser iTHERM ModuLine TM412Hygienic modular thermometer

Brand: Endress+Hauser SKU: TM412 Mfr Part #: TM412
Ships Same Day* Worldwide Shipping

Endress+Hauser TM412 - Temperature - Accuracy: class B acc. to IEC 60751 class A acc. to IEC 60751 class AA acc. to IEC 60751; Measuring principle: Resistance Temperature Detector; Certification: SIL (transmitter only).

This listing covers the Endress+Hauser TM412, a part number in the Temperature category. The manufacturer's published data for this part number specifies Accuracy: class B acc. to IEC 60751 class A acc. to IEC 60751 class AA acc. to IEC 60751 and Measuring principle: Resistance Temperature Detector.

depending on configuration iTHERM QuickSens: t90 = 1,5 s iTHERM StrongSens: t90 = 9,5 s

Key manufacturer data on file for this item includes Certification: SIL (transmitter only); Thermowell / protection tube: without incl. thermowell incl. Tee-/elbow thermowell; Insert / probe: mineral insulated (MI), flexible pipe version, isolated wires, not flexible; Outer diameter protection tube / Insert: 1/4'' (6,35 mm) 3/8'' (9,53 mm) 1/2" (12,7 mm); Max. immersion length on request: 48"; Material protection tube/ thermowell: 316L; Tip shape: straight reduced; Surface roughness Ra: 30 μin (0,76 μm) 15 μin (0,38 μm ) 15 μin (0,38 μm) electropolished; Max. process pressure (static): at 20 °C: 40 bar (580 psi); Integration head transmitter: yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS). The complete technical table is shown in the Specifications tab on this page.

Accuracy class B acc. to IEC 60751 class A acc. to IEC 60751 class AA acc. to IEC 60751
Certification SIL (transmitter only)
Characteristic / Application imperial style modular temperature assembly hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA) hygienic process connections with neck suitable for hazardous areas incl. protection tube iTHERM QuickSens for fastest response time iTHERM StrongSens for most robust design iTHERM QuickNeck for easy and cost saving recalibration
Ex - approvals ATEX Ex nA ATEX IECEx Ex ia, Ex tb CSA C/US IS, NI CSA NI CSA IS, NI FM NI FM IS, NI FM+CSA IS, NI
Insert / probe mineral insulated (MI), flexible pipe version, isolated wires, not flexible
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Material protection tube/ thermowell 316L
Max. immersion length on request 48"
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Measuring principle Resistance Temperature Detector
Operating temperature range PT100 WW: -200 °C … 600 °C (-328 °F … 1.112 °F) iTHERM StrongSens: -50 °C … 500 °C (-58 °F … 932 °F) iTHERM QuickSens: -50 °C … 200 °C (-58 °F … 392 °F) PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)
Outer diameter protection tube / Insert 1/4'' (6,35 mm) 3/8'' (9,53 mm) 1/2" (12,7 mm)
Process Connection Weld-in adapter Tri-clamp Clamp-connections according to ISO2852 G3/4" Liquiphant G1" Liquiphant Varivent T- and elbow thermowell
Response time depending on configuration iTHERM QuickSens: t90 = 1,5 s iTHERM StrongSens: t90 = 9,5 s
Surface roughness Ra 30 μin (0,76 μm) 15 μin (0,38 μm ) 15 μin (0,38 μm) electropolished
Thermowell / protection tube without incl. thermowell incl. Tee-/elbow thermowell
Tip shape straight reduced

Frequently Asked Questions

How do I get pricing for TM412?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the TM412?

TM412 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of TM412?

Key specifications include Accuracy: class B acc. to IEC 60751 class A acc. to IEC 60751 class AA acc. to IEC 60751; Certification: SIL (transmitter only); Characteristic / Application: imperial style modular temperature assembly hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA) hygienic process connections with neck suitable for hazardous areas incl. protection tube iTHERM QuickSens for fastest response time iTHERM StrongSens for most robust design iTHERM QuickNeck for easy and cost saving recalibration; Ex - approvals: ATEX Ex nA ATEX IECEx Ex ia, Ex tb CSA C/US IS, NI CSA NI CSA IS, NI FM NI FM IS, NI FM+CSA IS, NI. The full specification table on this page lists every published attribute for this part.

How quickly can TM412 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.