Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
SS2100 TDLAS gas analyzer
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Endress+Hauser SS2100 TDLAS gas analyzer

Brand: Endress+Hauser SKU: SS2100 Mfr Part #: SS2100
Ships Same Day* Worldwide Shipping

Endress+Hauser SS2100 - Optical analysis - Degree of protection: IP66, Type 4X; Channels: 3; Measuring principle: TDLAS.

Endress+Hauser SS2100 is a Optical analysis catalog item from Endress+Hauser. The manufacturer's published data for this part number specifies Degree of protection: IP66, Type 4X and Channels: 3.

Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O/CO2) Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs (H2S): 2, Flow Alarm, Validation Request Digital Outputs (H2O/CO2): 2, Concentration Alarm, General Fault

Published specifications for this part include Measuring principle: TDLAS; Hazardous area approvals: CSA Class I, Division 2 CSA Class I, Zone 2; Measured variables: Concentration Moisture Dew Point Cell Pressure Cell Temperature; Ambient temperature range: -20 to 50°C (-4 to 122°F) Optional: -10 to 60°C (14 to 140°F); Analyzer wetted materials: 316L stainless steel FKM O-Rings Glass. See the Specifications tab on this page for the full technical table.

Ambient temperature range -20 to 50°C (-4 to 122°F) Optional: -10 to 60°C (14 to 140°F)
Analyte and measurement ranges H2S (Hydrogen Sulfide): 0 to 10 ppmv (minimum) 0 to 1000 ppmv (maximum) H2O (Moisture): 0 to 100 ppmv (minimum) 0 to 5000 ppmv (maximum) CO2 (Carbon Dioxide): 0 to 5000 ppmv 0 to 5% volume 0 to 10% volume 0 to 20% volume
Analyzer wetted materials 316L stainless steel FKM O-Rings Glass
Channels 3
Communication Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O/CO2) Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs (H2S): 2, Flow Alarm, Validation Request Digital Outputs (H2O/CO2): 2, Concentration Alarm, General Fault
Degree of protection IP66, Type 4X
Hazardous area approvals CSA Class I, Division 2 CSA Class I, Zone 2
Housing materials Electronics: 304 or 316L stainless steel Sample System Enclosure: 304 or 316L stainless steel
Measured variables Concentration Moisture Dew Point Cell Pressure Cell Temperature
Measuring principle TDLAS
Operating Pressure Range Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
Power Supply 120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W (18 to 24 VDC - optional for electronics only) 3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Product headline Advanced multi-channel gas analyzer for hydrogen sulfide (H2S), moisture (H2O), and carbon dioxide (CO2), also known as a 3-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Frequently Asked Questions

How do I get pricing for SS2100?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the SS2100?

SS2100 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of SS2100?

Key specifications include Ambient temperature range: -20 to 50°C (-4 to 122°F) Optional: -10 to 60°C (14 to 140°F); Analyte and measurement ranges: H2S (Hydrogen Sulfide): 0 to 10 ppmv (minimum) 0 to 1000 ppmv (maximum) H2O (Moisture): 0 to 100 ppmv (minimum) 0 to 5000 ppmv (maximum) CO2 (Carbon Dioxide): 0 to 5000 ppmv 0 to 5% volume 0 to 10% volume 0 to 20% volume; Analyzer wetted materials: 316L stainless steel FKM O-Rings Glass; Channels: 3. The full specification table on this page lists every published attribute for this part.

How quickly can SS2100 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products