Endress+Hauser Raman Rxn-41 probe
Endress+Hauser KR41 - Optical analysis - Length: Maximum immersible length is dependent on material choice ft; Measuring principle: Raman spectroscopy; Diameter: 25.4 or 60.33 mm 1 or 2.375 inch (25.4 mm / 1 inch only for Grade 2.
This listing covers the Endress+Hauser KR41, a part number in the Optical analysis category. The manufacturer's published data for this part number specifies Length: Maximum immersible length is dependent on material choice ft and Measuring principle: Raman spectroscopy.
Nonexplosive environments: -30 to 70 °C / -22 to 158 °F Explosive environments: T3/T4: –20 to 70 °C / –4 to 158 °F T6: –20 to 65 °C / –4 to 149 °F Limited to normal ambient temperature IEC 60079-0 for Korea
The specification set recorded for this part number covers Diameter: 25.4 or 60.33 mm 1 or 2.375 inch (25.4 mm / 1 inch only for Grade 2 Titanium); Fiber optic cable: Cable sold separately; Laser wavelength: 532 nm, 785 nm, 1000 nm; Spectral coverage: Probe spectral coverage is limited by the coverage of the analyzer being used.; Maximum laser power into probehead (mW): < 499; Hazardous area certifications: ATEX, CSA, IECEx, UKCA, JPEx. See the Specifications tab on this page for the full technical table.
| Ambient temperature | Nonexplosive environments: -30 to 70 °C / -22 to 158 °F Explosive environments: T3/T4: –20 to 70 °C / –4 to 158 °F T6: –20 to 65 °C / –4 to 149 °F Limited to normal ambient temperature IEC 60079-0 for Korea |
|---|---|
| Diameter | 25.4 or 60.33 mm 1 or 2.375 inch (25.4 mm / 1 inch only for Grade 2 Titanium) |
| Fiber optic cable | Cable sold separately |
| Hazardous area certifications | ATEX, CSA, IECEx, UKCA, JPEx |
| Laser wavelength | 532 nm, 785 nm, 1000 nm |
| Length | Maximum immersible length is dependent on material choice ft |
| Maximum laser power into probehead (mW) | < 499 |
| Measuring principle | Raman spectroscopy |
| Pressure | Min pressure: Full vacuum (0 bara) but not ultrahigh vacuum (UHV) where outgassing may be a concern Max Pressure 25.4 mm / 1 inch standard probe: 141.5 barg / 2053 psig (316L stainless steel) 186.6 barg / 2707 psig (C276 alloy) 144.1 barg / 2090 psig (Grade 2 titanium) 25.4 mm / 1 inch cryogenic probe: 213.7 barg / 3100 psig (C276 alloy) 158.6 barg / 2300 psig (Hybrid metal combination) 60.33 mm / 2.375 inch probe: 49.7 barg / 721 psig (316L stainless steel) 68.8 barg / 998 psig (C276 alloy) 51.5 barg / 747 |
| Sample interface | Temperature (25.4 mm / 1 inch) standard configuration: -30 to 120 °C / -22 to 248 °F (316L stainless steel) -30 to 150 °C / -22 to 302 °F (C276 alloy) -30 to 150 °C / -22 to 302 °F (Grade 2 titanium) Temperature (25.4 mm / 1 inch) cryogenic configuration: -196 to 70°C / -320.8 to 158 °F (C276 alloy) -196 to 70 °C / -320.8 to 158 °F (Hybrid metal combination) Temperature (60.33 mm / 2.375 inch) standard configuration: -30 to 120°C / -22 to 248 °F (316L stainless steel) -30 to 150 °C / -22 to 302 °F (C276 all |
| Spectral coverage | Probe spectral coverage is limited by the coverage of the analyzer being used. |
| Wetted materials | 316L option Metal: 316L stainless steel Window: High-purity sapphire C276 option Metal: C276 alloy Window: High-purity sapphire Titanium option Metal: Grade 2 titanium Window: High-purity sapphire Hybrid metal combination option Metal: 316L stainless steel, C276 alloy Window: High-purity sapphire |
Frequently Asked Questions
How do I get pricing for KR41?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the KR41?
KR41 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of KR41?
Key specifications include Ambient temperature: Nonexplosive environments: -30 to 70 °C / -22 to 158 °F Explosive environments: T3/T4: –20 to 70 °C / –4 to 158 °F T6: –20 to 65 °C / –4 to 149 °F Limited to normal ambient temperature IEC 60079-0 for Korea; Diameter: 25.4 or 60.33 mm 1 or 2.375 inch (25.4 mm / 1 inch only for Grade 2 Titanium); Fiber optic cable: Cable sold separately; Hazardous area certifications: ATEX, CSA, IECEx, UKCA, JPEx. The full specification table on this page lists every published attribute for this part.
How quickly can KR41 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Raman Rxn-45 probe
Endress+Hauser Endress+Hauser Raman Rxn-40 probe
Endress+Hauser Endress+Hauser Raman Rxn-46 probe
Endress+Hauser Endress+Hauser Raman Rxn-30 probe
Endress+Hauser Endress+Hauser Raman bio multi optic
Endress+Hauser
Industrial & MRO Parts