Endress+Hauser Micropilot FMR66B – 80 GHz radar sensor
Endress+Hauser FMR66B - Level - Ambient temperature: -40 … +85 °C (-40 … +185 °F); Marine approval: ABS, LR, BV, RINA, DNV; Frequency: W-Band (~80 GHz).
This listing covers the Endress+Hauser FMR66B, a part number in the Level category. The manufacturer's published data for this part number specifies Ambient temperature: -40 … +85 °C (-40 … +185 °F) and Marine approval: ABS, LR, BV, RINA, DNV.
Display, Customized settings, App 'SmartBlue' for commissioning and operation via Bluetooth Heartbeat for batch detection; Gas-tight implementation; Overvoltage protection; PWIS free
The specification set recorded for this part number covers Frequency: W-Band (~80 GHz); Accuracy: +/- 3 mm (0.12 in); Measuring principle: Level radar solid; Process Connection: Thread: G1-1/2", MNPT1-1/2" Flange: UNI DN80...DN150 Mounting bracket; Process temperature: -40 … +130 °C (-40 … +266 °F); Process pressure / max. overpressure limit: Vacuum...16 bar (232 psi); Main wetted parts: PVDF or PTFE; Certificates / Approvals: IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex, INMETRO Ex, NEPSI Ex, UK Ex; Design approvals: Declaration of Conformity ASME B31.3; CRN approval; Hygienic approvals: EU Food Contact Material (EC) 1935/2004 US Food Contact Material FDA CFR 21; Max. measurement distance: 50 m (164 ft); Safety approvals: SIL. See the Specifications tab on this page for the full technical table.
| Accuracy | +/- 3 mm (0.12 in) |
|---|---|
| Ambient temperature | -40 … +85 °C (-40 … +185 °F) |
| Antenna | 1-1/2" / 40mm encapsulated, PVDF 2" / 50mm Drip-off, PTFE |
| Application limits | DK < 1.6 Reduction of the max. possible measuring range due to: Media with poor reflective properties cone of repose extremely loose surface of bulk solids, e.g. bulk solids with a low bulk density during pneumatic filling buildup, especially of moist products. Alternative for these applications: FMR67B |
| Certificates / Approvals | IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex, INMETRO Ex, NEPSI Ex, UK Ex |
| Characteristic / Application | For simple applications: Reliable, non-contact measurement of levels in silos or storage tanks for bulk solids |
| Communication | 4...20 mA HART Additional analog or switch output PROFIBUS PA PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
| Design approvals | Declaration of Conformity ASME B31.3; CRN approval |
| Frequency | W-Band (~80 GHz) |
| Hygienic approvals | EU Food Contact Material (EC) 1935/2004 US Food Contact Material FDA CFR 21 |
| Main wetted parts | PVDF or PTFE |
| Marine approval | ABS, LR, BV, RINA, DNV |
| Max. measurement distance | 50 m (164 ft) |
| Measuring principle | Level radar solid |
| Options | Display, Customized settings, App 'SmartBlue' for commissioning and operation via Bluetooth Heartbeat for batch detection; Gas-tight implementation; Overvoltage protection; PWIS free |
| Process Connection | Thread: G1-1/2", MNPT1-1/2" Flange: UNI DN80...DN150 Mounting bracket |
| Process pressure / max. overpressure limit | Vacuum...16 bar (232 psi) |
| Process temperature | -40 … +130 °C (-40 … +266 °F) |
| Safety approvals | SIL |
| Specialities | Heartbeat Verification + Monitoring, Bluetooth® Commissioning, operation and maintenance with SmartBlue App, HistoROM, RFID TAG for easy identification |
| Supply / Communication | 2-wire (HART/ PROFIBUS PA) PROFINET with Ethernet-APL Bluetooth® wireless technology |
Frequently Asked Questions
How do I get pricing for FMR66B?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the FMR66B?
FMR66B is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of FMR66B?
Key specifications include Accuracy: +/- 3 mm (0.12 in); Ambient temperature: -40 … +85 °C (-40 … +185 °F); Antenna: 1-1/2" / 40mm encapsulated, PVDF 2" / 50mm Drip-off, PTFE; Application limits: DK < 1.6 Reduction of the max. possible measuring range due to: Media with poor reflective properties cone of repose extremely loose surface of bulk solids, e.g. bulk solids with a low bulk density during pneumatic filling buildup, especially of moist products. Alternative for these applications: FMR67B. The full specification table on this page lists every published attribute for this part.
How quickly can FMR66B ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Micropilot FMR63B – 80 GHz radar sensor
Endress+Hauser Endress+Hauser Radar measurementMicropilot FMR67
Endress+Hauser Endress+Hauser Micropilot FMR67B – 80 GHz radar sensor
Endress+Hauser Endress+Hauser Micropilot FMR62B – 80 GHz radar sensor
Endress+Hauser Endress+Hauser Ultrasonic measurementTime-of-FlightProsonic FMU30
Endress+Hauser
Industrial & MRO Parts