Endress+Hauser HydrostaticLevel measurementDeltapilot FMB70

Brand: Endress+Hauser SKU: FMB70 Mfr Part #: FMB70
Ships Same Day* Worldwide Shipping

Endress+Hauser FMB70 - Pressure - Ambient temperature: -40°C...+85°C (-40°F...+185°F); Material housing: 316L, Die-cast aluminum; Options: HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing.

The Endress+Hauser FMB70 is part of the Pressure range in our industrial catalog. The manufacturer's published data for this part number specifies Ambient temperature: -40°C...+85°C (-40°F...+185°F) and Material housing: 316L, Die-cast aluminum.

4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)

Key manufacturer data on file for this item includes Options: HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing; Marine approval: GL/ DNV; Communication: 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus; Accuracy: Standard 0.1% Optional 0.075%; Measuring principle: Hydrostatic; Process Connection: Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K; Process temperature: -10°C...+100°C (+14°F...+212°F); Process pressure / max. overpressure limit: 40 bar (600 psi); Main wetted parts: Alloy C 316L; Certificates / Approvals: ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC; Specialities: Diagnostic functions; Process connection hygienic: Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD. The complete technical table is shown in the Specifications tab on this page.

Accuracy Standard 0.1% Optional 0.075%
Ambient temperature -40°C...+85°C (-40°F...+185°F)
Application limits Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version
Characteristic / Application Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed
Communication 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Design approvals EN10204-3.1 NACE MR0175, MR0103
Drinking water approvals NSF
Fill fluid Inert oil, Synthetic oil
Hygienic approvals 3A, EHEDG CoC ASME-BPE
Long term stability 0.05 % of URL/year
Main wetted parts Alloy C 316L
Marine approval GL/ DNV
Marine approvals GL, DNV
Material gasket None, measuring cell welded
Material housing 316L, Die-cast aluminum
Material process membrane 316L, AlloyC, Gold-Rhodium
Max. measurement distance 100 m (328 ft) H2O
Max. overpressure limit 40 bar (600 psi)
Measuring cell 100 mbar...10 bar (1.5 psi...150 psi)
Measuring principle Hydrostatic
Options HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing
Pressure measuring range 100 mbar...10 bar (1.5 psi...150 psi)
Process Connection Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K
Process connection hygienic Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD
Process pressure / max. overpressure limit 40 bar (600 psi)
Process temperature -10°C...+100°C (+14°F...+212°F)
Reference Accuracy Standard 0.1% Optional 0.075%
Safety approvals SIL
Smallest calibratable span 25 mbar (3.63 psi)
Specialities Diagnostic functions
Supply / Communication 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex)
Supply voltage 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Vacuum resistance 0 mbar abs.

Frequently Asked Questions

How do I get pricing for FMB70?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the FMB70?

FMB70 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of FMB70?

Key specifications include Accuracy: Standard 0.1% Optional 0.075%; Ambient temperature: -40°C...+85°C (-40°F...+185°F); Application limits: Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure; Certificates / Approvals: ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC. The full specification table on this page lists every published attribute for this part.

How quickly can FMB70 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products