Endress+Hauser HydrostaticLevel measurementDeltapilot FMB70
Endress+Hauser FMB70 - Pressure - Ambient temperature: -40°C...+85°C (-40°F...+185°F); Material housing: 316L, Die-cast aluminum; Options: HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing.
The Endress+Hauser FMB70 is part of the Pressure range in our industrial catalog. The manufacturer's published data for this part number specifies Ambient temperature: -40°C...+85°C (-40°F...+185°F) and Material housing: 316L, Die-cast aluminum.
4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Key manufacturer data on file for this item includes Options: HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing; Marine approval: GL/ DNV; Communication: 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus; Accuracy: Standard 0.1% Optional 0.075%; Measuring principle: Hydrostatic; Process Connection: Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K; Process temperature: -10°C...+100°C (+14°F...+212°F); Process pressure / max. overpressure limit: 40 bar (600 psi); Main wetted parts: Alloy C 316L; Certificates / Approvals: ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC; Specialities: Diagnostic functions; Process connection hygienic: Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD. The complete technical table is shown in the Specifications tab on this page.
| Accuracy | Standard 0.1% Optional 0.075% |
|---|---|
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Application limits | Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC |
| Characteristic | Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version |
| Characteristic / Application | Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Design approvals | EN10204-3.1 NACE MR0175, MR0103 |
| Drinking water approvals | NSF |
| Fill fluid | Inert oil, Synthetic oil |
| Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
| Long term stability | 0.05 % of URL/year |
| Main wetted parts | Alloy C 316L |
| Marine approval | GL/ DNV |
| Marine approvals | GL, DNV |
| Material gasket | None, measuring cell welded |
| Material housing | 316L, Die-cast aluminum |
| Material process membrane | 316L, AlloyC, Gold-Rhodium |
| Max. measurement distance | 100 m (328 ft) H2O |
| Max. overpressure limit | 40 bar (600 psi) |
| Measuring cell | 100 mbar...10 bar (1.5 psi...150 psi) |
| Measuring principle | Hydrostatic |
| Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
| Pressure measuring range | 100 mbar...10 bar (1.5 psi...150 psi) |
| Process Connection | Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
| Process pressure / max. overpressure limit | 40 bar (600 psi) |
| Process temperature | -10°C...+100°C (+14°F...+212°F) |
| Reference Accuracy | Standard 0.1% Optional 0.075% |
| Safety approvals | SIL |
| Smallest calibratable span | 25 mbar (3.63 psi) |
| Specialities | Diagnostic functions |
| Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) |
| Supply voltage | 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) |
| Vacuum resistance | 0 mbar abs. |
Frequently Asked Questions
How do I get pricing for FMB70?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the FMB70?
FMB70 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of FMB70?
Key specifications include Accuracy: Standard 0.1% Optional 0.075%; Ambient temperature: -40°C...+85°C (-40°F...+185°F); Application limits: Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure; Certificates / Approvals: ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC. The full specification table on this page lists every published attribute for this part.
How quickly can FMB70 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser HydrostaticLevel measurementDeltapilot FMB53
Endress+Hauser Endress+Hauser Electronicdifferential pressureDeltabar FMD71
Endress+Hauser Endress+Hauser Electronicdifferential pressureDeltabar FMD72
Endress+Hauser Endress+Hauser HydrostaticLevel measurementDeltapilot FMB52
Endress+Hauser Endress+Hauser Differential pressureDeltabar FMD77
Endress+Hauser
Industrial & MRO Parts