Endress+Hauser HydrostaticLevel measurementDeltapilot FMB51

Brand: Endress+Hauser SKU: FMB51 Mfr Part #: FMB51
Ships Same Day* Worldwide Shipping

Endress+Hauser FMB51 - Pressure - Ambient temperature: -40°C...85°C (-40°F...185°F); Material housing: 316L, Die-cast aluminum; Options: Separate housing Initial device settings Overvoltage protection.

The Endress+Hauser FMB51 is part of the Pressure range in our industrial catalog. The manufacturer's published data for this part number specifies Ambient temperature: -40°C...85°C (-40°F...185°F) and Material housing: 316L, Die-cast aluminum.

4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)

Key manufacturer data on file for this item includes Options: Separate housing Initial device settings Overvoltage protection; Communication: 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus; Accuracy: Standard 0.2% Optional 0.1%; Measuring principle: Hydrostatic; Process Connection: Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K; Process temperature: -10°C...85°C (14°F…212°F); Process pressure / max. overpressure limit: 40 bar (600 psi); Main wetted parts: Alloy C 316L optional coating AuPt; Certificates / Approvals: ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI; Design approvals: EN 10204-3.1 NACE MR0175; Max. measurement distance: 100m (328ft) H2O; Reference Accuracy: Standard 0.2 % Optional 0.1 %. The complete technical table is shown in the Specifications tab on this page.

Accuracy Standard 0.2% Optional 0.1%
Ambient temperature -40°C...85°C (-40°F...185°F)
Application limits If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Rod version
Characteristic / Application Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed Rod version
Communication 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Design approvals EN 10204-3.1 NACE MR0175
Drinking water approvals KTW/ NSF
Fill fluid Inert oil, Synthetic oil
Long term stability 0.05 % of URL/ year
Main wetted parts Alloy C 316L optional coating AuPt
Material gasket Viton, EPDM, Kalrez, none
Material housing 316L, Die-cast aluminum
Material process membrane 316L, AlloyC Gold-Rhodium
Max. measurement distance 100m (328ft) H2O
Max. overpressure limit 40 bar (600 psi)
Max. Turn down 100:1
Measuring cell 100 mbar...10 bar (1.5 psi...150 psi)
Measuring principle Hydrostatic
Options Separate housing Initial device settings Overvoltage protection
Pressure measuring range 100 mbar...10 bar (1.5 psi...150 psi)
Process Connection Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K
Process pressure / max. overpressure limit 40 bar (600 psi)
Process temperature -10°C...85°C (14°F…212°F)
Reference Accuracy Standard 0.2 % Optional 0.1 %
Safety approvals Overfill protection WHG SIL
Smallest calibratable span 10 mbar (1.45 psi)
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics) diagnostic functions Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
Supply / Communication 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex)
Supply voltage 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Vacuum resistance 0 mbar abs.

Frequently Asked Questions

How do I get pricing for FMB51?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the FMB51?

FMB51 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of FMB51?

Key specifications include Accuracy: Standard 0.2% Optional 0.1%; Ambient temperature: -40°C...85°C (-40°F...185°F); Application limits: If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure; Certificates / Approvals: ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI. The full specification table on this page lists every published attribute for this part.

How quickly can FMB51 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products