Endress+Hauser Prosonic Flow Clamp On 93P

Brand: Endress+Hauser SKU: 93P Mfr Part #: 93P
Ships Same Day* Worldwide Shipping

Endress+Hauser 93P - Flow measurement - Power Supply: 85 to 260 V AC 20 to 55 V AC 16 to 62V DC; Measuring range: 0.3 to 10 m/s (1 to 33 ft/s); Measuring principle: Ultrasonic flow.

The Endress+Hauser 93P is part of the Flow measurement range in our industrial catalog. The manufacturer's published data for this part number specifies Power Supply: 85 to 260 V AC 20 to 55 V AC 16 to 62V DC and Measuring range: 0.3 to 10 m/s (1 to 33 ft/s).

IP67, type 4X for transmitter IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosure

Key manufacturer data on file for this item includes Measuring principle: Ultrasonic flow; Outputs: 1x 4-20 mA HART 1x Pulse/frequency/switch output (passive); Display/Operation: 4 lines backlit display with three optical keys; Product safety: EAC marking; Hazardous area approvals: ATEX, FM/CSA, NEPSI, JPN; Metrological approvals and certificates: Flowmeter verification for DN15, 25, 40, 50 & 100 only; Max. measurement error: Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to DN200 ±2% o.r. above DN200; Max. process pressure: N/A; Ambient temperature range: -20 to +60 °C (-4 to +140 °F) -40 to +60 °C (-40 to +140 °F) optional; Sensor housing material: N/A; Transmitter housing material: Wall-mounted housing: powder-coated die-cast aluminum; Inputs: N/A. See the Specifications tab on this page for the full technical table.

Ambient temperature range -20 to +60 °C (-4 to +140 °F) -40 to +60 °C (-40 to +140 °F) optional
Degree of protection IP67, type 4X for transmitter IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosure
Digital communication HART PROFIBUS PA Profibus DP FOUNDATION Fieldbus
Display/Operation 4 lines backlit display with three optical keys
Hazardous area approvals ATEX, FM/CSA, NEPSI, JPN
Inputs N/A
Marine approvals and certificates Marine certificate
Max. measurement error Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to DN200 ±2% o.r. above DN200
Max. process pressure N/A
Measured variables Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer
Measuring principle Ultrasonic flow
Measuring range 0.3 to 10 m/s (1 to 33 ft/s)
Medium temperature range DN15 to 65 -40 to +100°C (-40 +212 °F) -40 to +150°C (-40 +302 °F) option DN50 to 4000 -40 to +80°C (-40 +276 °F) -40 to +170°C (-40 +338 °F) option
Metrological approvals and certificates Flowmeter verification for DN15, 25, 40, 50 & 100 only
Nominal diameter range Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160") Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Other approvals and certificates Flowmeter verification for DN15, 25, 40, 50 & 100 only Marine certificate EAC marking
Outputs 1x 4-20 mA HART 1x Pulse/frequency/switch output (passive)
Power Supply 85 to 260 V AC 20 to 55 V AC 16 to 62V DC
Product headline std_productprofile_product_usp_8209. std_productprofile_product_usp2_58665_1571899493. std_productprofile_product_field_of_application_8210.
Product safety EAC marking
Sensor features std_productprofile_product_benefits_8212. Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability. std_successorproducts_product_differentiating_tech_features_58667_1571900174. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). std_successorproducts_product_differentiating_tech_features_58669_1571900174.
Sensor housing material N/A
Transmitter features std_productprofile_product_benefits_8192. std_productprofile_product_benefits_8193. std_productprofile_product_benefits_58666_1571901005. std_successorproducts_product_differentiating_tech_features_58672_1571901893. std_successorproducts_product_differentiating_tech_features_58668_1571902040. std_successorproducts_product_differentiating_tech_features_58670_1571902090.
Transmitter housing material Wall-mounted housing: powder-coated die-cast aluminum
Wetted materials Clamp on system: Sensor holder 1.4308/CF-8 Sensor housing 1.4301/304 Strapping bands 1.4301/304

Frequently Asked Questions

How do I get pricing for 93P?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 93P?

93P is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 93P?

Key specifications include Ambient temperature range: -20 to +60 °C (-4 to +140 °F) -40 to +60 °C (-40 to +140 °F) optional; Degree of protection: IP67, type 4X for transmitter IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosure; Digital communication: HART PROFIBUS PA Profibus DP FOUNDATION Fieldbus; Display/Operation: 4 lines backlit display with three optical keys. The full specification table on this page lists every published attribute for this part.

How quickly can 93P ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.