Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
Prosonic Flow Clamp-On 91W
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Endress+Hauser Prosonic Flow Clamp-On 91W

Brand: Endress+Hauser SKU: 91W Mfr Part #: 91W
Ships Same Day* Worldwide Shipping

Endress+Hauser 91W - Flow measurement - Power Supply: AC 85 to 250 V 20 to 28 V DC 11 to 40 V; Measuring range: 0.3 to 10 m/s (1 to 33 ft/s); Outputs: 1x 4-20 mA HART (active).

In our catalog, the 91W from Endress+Hauser is listed under the Flow measurement category. The manufacturer's published data for this part number specifies Power Supply: AC 85 to 250 V 20 to 28 V DC 11 to 40 V and Measuring range: 0.3 to 10 m/s (1 to 33 ft/s).

IP67, type 4X for transmitter IP67 type 4X for sensors IP68 type 6P for sensors (option). IP67 NEMA 4X

The specification set recorded for this part number covers Outputs: 1x 4-20 mA HART (active) 1x Pulse/frequency/switch output (passive); Nominal diameter range: Single channel, 1 or 2 paths : DN15 to 2000 (1/2 to 80"); Display/Operation: 2 lines backlit display with 3 push button; Product safety: CE, C-Tick, EAC marking; Hazardous area approvals: Non hazardous area FM, CSA; Metrological approvals and certificates: Flowmeter verification for DN15, 25, 40, 50 & 100 only; Measured variables: Volume flow, sound velocity, flow velocity, signal strength, totalizer; Max. measurement error: Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200; Max. process pressure: N/A; Medium temperature range: -20 to +80°C (-4 to +176 °F) 0 to +130°C (32 to +265 °F) option; Ambient temperature range: -20 to +60 °C (-4 to +140 °F); Sensor housing material: N/A. The complete technical table is shown in the Specifications tab on this page.

Ambient temperature range -20 to +60 °C (-4 to +140 °F)
Degree of protection IP67, type 4X for transmitter IP67 type 4X for sensors IP68 type 6P for sensors (option). IP67 NEMA 4X
Digital communication HART
Display/Operation 2 lines backlit display with 3 push button
Hazardous area approvals Non hazardous area FM, CSA
Inputs N/A
Max. measurement error Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200
Max. process pressure N/A
Measured variables Volume flow, sound velocity, flow velocity, signal strength, totalizer
Measuring range 0.3 to 10 m/s (1 to 33 ft/s)
Medium temperature range -20 to +80°C (-4 to +176 °F) 0 to +130°C (32 to +265 °F) option
Metrological approvals and certificates Flowmeter verification for DN15, 25, 40, 50 & 100 only
Nominal diameter range Single channel, 1 or 2 paths : DN15 to 2000 (1/2 to 80")
Other approvals and certificates Flowmeter verification for DN15, 25, 40, 50 & 100 only EAC marking
Outputs 1x 4-20 mA HART (active) 1x Pulse/frequency/switch output (passive)
Power Supply AC 85 to 250 V 20 to 28 V DC 11 to 40 V
Product headline Device with automatic frequency scan for maximum measuring performance and cost-effective transmitter. Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater.
Product safety CE, C-Tick, EAC marking
Sensor features Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability. Medium temperature: –20 to +80 °C (-4 to +176 °F). Degree of protection IP68 (Type 6P enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6.
Sensor housing material N/A
Transmitter features Economical transmitter – designed for easy applications. Fast and reliable commissioning – Quick Setup menu for installation. Automatic recovery of data for servicing. Aluminium field transmitter housing. 2-line display with push buttons. HART.
Transmitter housing material AlSi10Mg, coated
Wetted materials Clamp on system: Sensor holder 1.4308/CF-8 Sensor housing 1.4301/304 Strapping bands 1.4301/304

Frequently Asked Questions

How do I get pricing for 91W?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 91W?

91W is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 91W?

Key specifications include Ambient temperature range: -20 to +60 °C (-4 to +140 °F); Degree of protection: IP67, type 4X for transmitter IP67 type 4X for sensors IP68 type 6P for sensors (option). IP67 NEMA 4X; Digital communication: HART; Display/Operation: 2 lines backlit display with 3 push button. The full specification table on this page lists every published attribute for this part.

How quickly can 91W ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products