Endress+Hauser Promass 84A

Brand: Endress+Hauser SKU: 84A Mfr Part #: 84A
Ships Same Day* Worldwide Shipping

Endress+Hauser 84A - Flow measurement - Ambient temperature: -20...+65°C (-4...+140°F); Degree of protection: IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure; + output: 4...20mA Pulse/Frequency (10KHz, 90° phase shifted, active/passive).

Endress+Hauser 84A is a Flow measurement catalog item from Endress+Hauser. The manufacturer's published data for this part number specifies Ambient temperature: -20...+65°C (-4...+140°F) and Degree of protection: IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure.

4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive), phase‐shifted pulse Relay

The specification set recorded for this part number covers + output: 4...20mA Pulse/Frequency (10KHz, 90° phase shifted, active/passive); Power Supply: DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz); Measuring range: 0 to 450 kg/h (0 to 16.5 lb/min); Nominal diameter range: DN 2 to 4 (¹⁄₁₂ to ¹⁄₈"); Process pressure: PN 16...400 Cl 150...600 JIS 10...63K; Product safety: CE, C-tick, EAC marking; Hazardous area approvals: ATEX, IECEx, FM, CSA, NEPSI, EAC; Material certificates: 3.1 material; Process temperature: -50...+200°C (-58...+392°F); Max. process pressure: PN 40, Class 300, 20K, 400 bar (5800 psi); Medium temperature range: –50 to +200 °C (–58 to +392 °F); Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F). The complete technical table is shown in the Specifications tab on this page.

+ output 4...20mA Pulse/Frequency (10KHz, 90° phase shifted, active/passive)
Ambient temperature -20...+65°C (-4...+140°F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Certificates / Approvals ATEX FM CSA TIIS
Characteristic / Application Coriolis mass flowmeter for custody transfer application.
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Digital communication HART Modbus RS485
Display/Operation 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI, EAC
Hygienic approvals and certificates 3-A
Inputs 1 modular input: status
Material certificates 3.1 material
Max. measurement error Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³
Max. process pressure PN 40, Class 300, 20K, 400 bar (5800 psi)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Measuring range 0 to 450 kg/h (0 to 16.5 lb/min)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR Custody transfer approvals: MI-002 (gas), MI-005 (liquid) , PTB 7.251 (gas)
Nominal diameter range DN 2 to 4 (¹⁄₁₂ to ¹⁄₈")
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, CRN, 3-A
Outputs 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive), phase‐shifted pulse Relay
Power Supply DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Pressure approvals and certificates CRN
Process pressure PN 16...400 Cl 150...600 JIS 10...63K
Process temperature -50...+200°C (-58...+392°F)
Product headline The single‐tube flowmeter for smallest quantities with custody transfer functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Product safety CE, C-tick, EAC marking
Sensor features Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 2 to 4 (¹⁄₁₂ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter features Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
Transmitter housing material Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast
Wetted materials Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Wetted parts 904L/1.4539 Alloy C-22/2.4602

Frequently Asked Questions

How do I get pricing for 84A?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 84A?

84A is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 84A?

Key specifications include + output: 4...20mA Pulse/Frequency (10KHz, 90° phase shifted, active/passive); Ambient temperature: -20...+65°C (-4...+140°F); Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F); Certificates / Approvals: ATEX FM CSA TIIS. The full specification table on this page lists every published attribute for this part.

How quickly can 84A ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products