Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
Promass 80H
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Endress+Hauser Promass 80H

Brand: Endress+Hauser SKU: 80H Mfr Part #: 80H
Ships Same Day* Worldwide Shipping

Endress+Hauser 80H - Flow measurement - Ambient temperature: -20...+65°C (-4...+140°F); Degree of protection: IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure; + output: 4...20 mA Pulse/Frequency Status.

The Endress+Hauser 80H is part of the Flow measurement range in our industrial catalog. The manufacturer's published data for this part number specifies Ambient temperature: -20...+65°C (-4...+140°F) and Degree of protection: IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure.

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Published specifications for this part include + output: 4...20 mA Pulse/Frequency Status; Power Supply: DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz); Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min); Measuring principle: Coriolis; Nominal diameter range: DN 8 to 50 (³⁄₈ to 2"); Process pressure: PN 40 Cl 150...300 JIS 10...20K; Product safety: CE, C-tick, EAC marking; Hazardous area approvals: ATEX, IECEx, FM, CSA, NEPSI; Material certificates: 3.1 material; Process temperature: -50...+200°C (-58...+392°F); Max. process pressure: PN 40, Class 300, 20K; Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F). The complete technical table is shown in the Specifications tab on this page.

+ output 4...20 mA Pulse/Frequency Status
Ambient temperature -20...+65°C (-4...+140°F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Certificates / Approvals ATEX FM CSA
Characteristic / Application Balanced single-tube system, "Fit-and-Forget" installation Design: Easy to clean, hygienic, careful handling of the medium - chemically resistant material
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Digital communication HART PROFIBUS PA
Display/Operation 2‐line backlit display with push buttons Configuration via local display and operating tools possible
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Inputs Status input
Material certificates 3.1 material
Max. measurement error Mass flow (liquid): ±0.15 % Volume flow (liquid): ±0.15 % Mass flow (gas, Tantalum only): ±0.5 % Density (liquid): ±0.0005 g/cm³
Max. process pressure PN 40, Class 300, 20K
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Measuring principle Coriolis
Measuring range 0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature range Tantalum: –50 to +150 °C (–58 to +302 °F) Ziconium: –50 to +200 °C (–58 to +392 °F)
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Nominal diameter range DN 8 to 50 (³⁄₈ to 2")
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL PED, CRN
Outputs 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive)
Power Supply DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Pressure approvals and certificates PED, CRN
Process pressure PN 40 Cl 150...300 JIS 10...20K
Process temperature -50...+200°C (-58...+392°F)
Product headline The chemically resistant single‐tube flowmeter with a compact or remote transmitter. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
Product safety CE, C-tick, EAC marking
Sensor features Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Transmitter housing material Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast
Wetted materials Measuring tube: Tantalum 2.5W; 702 (UNS R60702) Connection: Tantalum; 702 (UNS R60702)
Wetted parts Zirconium 702/R60702

Frequently Asked Questions

How do I get pricing for 80H?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 80H?

80H is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 80H?

Key specifications include + output: 4...20 mA Pulse/Frequency Status; Ambient temperature: -20...+65°C (-4...+140°F); Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F); Certificates / Approvals: ATEX FM CSA. The full specification table on this page lists every published attribute for this part.

How quickly can 80H ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.