Promag 10P
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Endress+Hauser Promag 10P

Brand: Endress+Hauser SKU: 10P Mfr Part #: 10P
Ships Same Day* Worldwide Shipping

Endress+Hauser 10P - Flow measurement - Power Supply: DC 11 to 40 V AC 85 to 250 V (45 to 65 Hz) AC 20 to 28 V (45 to 65 Hz); Measuring range: 4 dm3/min to 9600 m3/h.

Endress+Hauser 10P is a Flow measurement catalog item from Endress+Hauser. The manufacturer's published data for this part number specifies Power Supply: DC 11 to 40 V AC 85 to 250 V (45 to 65 Hz) AC 20 to 28 V (45 to 65 Hz) and Measuring range: 4 dm3/min to 9600 m3/h (0.5 gal/min to 44000 gal/min).

Standard: IP 67 (Type 4X enclosure) for transmitter and sensor Optional: IP 68 (Type 6P enclosure) for remote version of sensor

Published specifications for this part include Measuring principle: Electromagnetic; Outputs: 4‐20 mA HART (active) Pulse/switch output (passive); Nominal diameter range: DN 15 to 600 1/2" to 24"; Product safety: CE, C-tick, EAC marking; Hazardous area approvals: FM CSA; Wetted materials: Liner: PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Measured variables: Volume flow; Max. measurement error: Volume flow: ±0,5% o.r. ± 2 mm/s (±0,5% o.r. ± 0,08 in/s); Max. process pressure: PN40 Cl. 300 JIS 20K AS 2129 Table E; Medium temperature range: –40 to +130°C (–40 to +266°F); Ambient temperature range: –40 to +60 °C (–40 to +140 °F); Transmitter housing material: Powder-coated die-cast aluminum. The complete technical table is shown in the Specifications tab on this page.

Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Degree of protection Standard: IP 67 (Type 4X enclosure) for transmitter and sensor Optional: IP 68 (Type 6P enclosure) for remote version of sensor
Digital communication HART
Display/Operation 2‐line display with push buttons Configuration via local display and operating tools possible
Hazardous area approvals FM CSA
Inputs None
Max. measurement error Volume flow: ±0,5% o.r. ± 2 mm/s (±0,5% o.r. ± 0,08 in/s)
Max. process pressure PN40 Cl. 300 JIS 20K AS 2129 Table E
Measured variables Volume flow
Measuring principle Electromagnetic
Measuring range 4 dm3/min to 9600 m3/h (0.5 gal/min to 44000 gal/min)
Medium temperature range –40 to +130°C (–40 to +266°F)
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Nominal diameter range DN 15 to 600 1/2" to 24"
Outputs 4‐20 mA HART (active) Pulse/switch output (passive)
Power Supply DC 11 to 40 V AC 85 to 250 V (45 to 65 Hz) AC 20 to 28 V (45 to 65 Hz)
Pressure approvals and certificates PED
Product headline std_productprofile_product_usp_34716_1509006628. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Product safety CE, C-tick, EAC marking
Sensor features Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). std_successorproducts_product_differentiating_tech_features_35249_1509523846. std_successorproducts_product_differentiating_tech_features_35251_1509523847.
Sensor housing material DN 15 to 300 (½ to 12"): AlSi10Mg, coated DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Transmitter features std_productprofile_product_benefits_34707_1508943674. std_productprofile_product_benefits_34705_1508943673. std_productprofile_product_benefits_34706_1508943673. 2-line display with push buttons. Device as compact or remote version. HART.
Transmitter housing material Powder-coated die-cast aluminum
Wetted materials Liner: PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

Frequently Asked Questions

How do I get pricing for 10P?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 10P?

10P is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 10P?

Key specifications include Ambient temperature range: –40 to +60 °C (–40 to +140 °F); Degree of protection: Standard: IP 67 (Type 4X enclosure) for transmitter and sensor Optional: IP 68 (Type 6P enclosure) for remote version of sensor; Digital communication: HART; Display/Operation: 2‐line display with push buttons Configuration via local display and operating tools possible. The full specification table on this page lists every published attribute for this part.

How quickly can 10P ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.