Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
280D-F12S-10C-CRW
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley ArmorStart Direct Online Starter 280D-F12S-10C-CRW

Brand: Allen-Bradley SKU: 280D-F12S-10C-CRW
Ships Same Day* Worldwide Shipping

Allen-Bradley 280D-F12S-10C-CRW - industrial components - Operating Temperature: -20 °C; Lifecycle Status: Discontinued; Build America, Buy America: No.

Allen-Bradley 280D-F12S-10C-CRW is a industrial components catalog item from Allen-Bradley. The manufacturer's published data for this part number specifies Operating Temperature: -20 °C and Lifecycle Status: Discontinued.

Key manufacturer data on file for this item includes Build America, Buy America: No; Repair Options Available: No; Sub Brand: ArmorStart; Degree of protection (IP): IP67; Degree of protection (NEMA): 4; Altitude: 2000 m; Number of poles: 3; Shipping weight, approx: 6.8 kg; Contactor size: 12 A; Trip Class: Class 10, 15, 20; Tightening torque: Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal); Application in industrial area permitted: true. The complete technical table is shown in the Specifications tab on this page.

3-phase power/motor cable connection Conduit entrance with no motor cable
Altitude 2000 m
Application in industrial area permitted true
Application in industrial area permitted (SCPD list) Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Backplane current load Output rating- sourced from control circuit: 400 mA
Baud rates DeviceNet communications: 500 kbps
Build America, Buy America No
Communication DeviceNet
Conducted radio frequency emissions Class A
Conection type Quick disconnects
Contactor current (hold in) Power requirements: 0.30 A without HOA
Contactor current (pick up) Power requirements: 1.09 A without HOA
Contactor size 12 A
Control Voltage Power requirements: 24V DC without HOA
Conventional thermal current (Ith) Output rating- sourced from control circuit: total of both outputs ≤2 A
Current available Sensor source: 50 mA maximum per input, 200 mA total
Degree of protection (IP) IP67
Degree of protection (NEMA) 4
Depth, approx Motor connection 243 mm (9.57 in) M35 cordset
DeviceNet input current 364mA @ 11V DC - 4.0 W
DeviceNet input current surge 15 A for 250 µs
DeviceNet supply voltage rating Range 11...25V DC @ 24V DC Nominal
Dielectric withstand Power circuit: 2500V AC per IEC
Disconnect Motor disconnect
Distance, max DeviceNet communications: 500 m (1630 ft) @ 125 kbps
Electrostatic discharge 4 kV contact and 8 kV air
External devices powered by DeviceNet 50 mA - total 200 mA
Fast transient 2 kV
Height, approx 287.5 mm
Humidity 5…95% (noncondensing)
Input compatibility IEC 1+
Input filter - software selectable Settable from 0...64 ms in 1 ms increments (ON to OFF)
Input OFF-state current <1.5 mA
Input OFF-state voltage 0…5V DC
Input ON-state current 7.2mA @ 24V DC
Input ON-state voltage 10...26V DC
Insulation voltage Power circuit: rated 600V
Kind of current Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
Lifecycle Status Discontinued
Mains frequency 50/60 Hz
Number of contacts Output rating- sourced from control circuit: 2
Number of digital inputs 4
Number of digital outputs 2
Number of poles 3
Operating frequency Power circuit: 50/60 Hz
Operating Temperature -20 °C
Operational power rating Full voltage starters - IP67/Type 4/12: 3Hp @ 460V AC, 60 Hz
Outputs current (2) 1 A each, max External devices powered by control voltage: 2 A without HOA
Overload current, min 1.1 A
Overvoltage category Control circuit: III per IEC
Pollution degree 3
Product type Full voltage starter
Protection against shock Power circuit: IP2X per IEC
Radiated emissions Class A, group 1, equivalent to C2 emissions
Radio frequency electromagnetic field 10 V/m
Rated impulse voltage Power circuit: 4 kV
Rated input operation voltage 24V DC
Rated operation voltage Power circuit: 380Y/220...480Y/277V AC
Rated operational current Power circuit: 5.5 A maximum
Rated output operation voltage Sourced from control circuit: 240V AC / 30V DC
Repair Options Available No
RMS symmetrical amperes 65 kA @ 480Y/277V
Safety Hardwired Safety (STO)
Shipping weight, approx 6.8 kg
Shock opsal: 15 G
Short circuit protection 10 A rated device
Short circuit protection device performance (SCPD) type Type 1
Short circuit rating 30 kA
Storage and transportation temperature -25 °C
Sub Brand ArmorStart
Supporting protocol for DeviceNet true
Supporting protocol for DeviceNet Safety true
Surge transient 1 kV L-L, 2 kV L-N (earth)
Tightening torque Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Total control power (hold in) Power requirements: 7.2 W without HOA
Total control power (hold in), max External devices powered by control voltage: 58 W with HOA
Total control power (pick up) Power requirements: 26.0 W without HOA
Total control power (pick up), max External devices powered by control voltage: 73 W with HOA
Total w/max. sensor inputs (4) 367mA @ 24V DC - 8.0 W
Trip Class Class 10, 15, 20
Trip rating 120% of full load current (FLC) setting
Type of contacts Output rating- sourced from control circuit: normally open (NO)
Type of control circuit Output rating- sourced from control circuit: electromechanical relay
Utilization category Power circuit: AC-3 per IEC
Vibration opsal, 1 G, 0.15 mm (0.006 in) displacement
Voltage status only Sensor source: 11...25V DC from DeviceNet
Width, approx 351 mm
Wire size Power and ground terminal: 1.5...5.3 mm² per IEC (primary terminal)
Wire strip length Power and ground terminals: 0.35 in (9 mm)

Frequently Asked Questions

How do I get pricing for 280D-F12S-10C-CRW?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 280D-F12S-10C-CRW?

280D-F12S-10C-CRW is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 280D-F12S-10C-CRW?

Key specifications include 3-phase power/motor cable connection: Conduit entrance with no motor cable; Altitude: 2000 m; Application in industrial area permitted: true; Application in industrial area permitted (SCPD list): Size per NFPA 70 (NEC) or NFPA 79 for group motor applications. The full specification table on this page lists every published attribute for this part.

How quickly can 280D-F12S-10C-CRW ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products