Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
20LE800N3ENNKC20WA
Request a Quote Email orderdesk@kkmsolutions.com for pricing and availability.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley PowerFlex 700L AC Drive 20L 20LE800N3ENNKC20WA

Brand: Allen-Bradley SKU: 20LE800N3ENNKC20WA
Ships Same Day* Worldwide Shipping
AC input overvoltage trip 760V @ 600V
AC input undervoltage trip 340V @ 600V
Acceleration/deceleration Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Active converter cassette terminal blocks-P1 & P2 Active converter AC power and control wiring for control terminal
Actual short circuit rating Determined by AIC rating of installed circuit breaker.
Additional configuration None
Altitude 1000 m (3280 ft) at rated current
Application in domestic- and commercial area permitted true
Application in industrial area permitted true
Atmosphere Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
Brake IGBT No brake IGBT
Brake Resistor No internal brake resistor
Build America, Buy America No
Bussmann fuse current rating 1250A @ 810V DC
Carrier frequency 2 or 4 kHz drive rating based on 4 kHz
Circuit breaker current rating 1500A @ 575...690V AC input voltage
Control logic noise immunity Showering arc transients upto 1500V peak
Control method Sine coded PWM with progmable carrier frequency
Control options 700 vector control with 115V AC I/O
Coolant Water
Coolant flow rating, max 94.6 l/min
Coolant flow rating, min 56.8 l/min
Coolant temperature 0 °C
Coolant type WEG50 equals good quality or distilled water with approved inhibited ethylene glycol, 50% glycol by volume or WPG50 equals good quality or distilled water with approved inhibited propylene glycol, 50% glycol by volume.
Current limit capability Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Custom option None
DC bus overvoltage trip 1168V @ 600V
DC bus test point socket 4 mm socket for DC bus voltage measurement only (2 terminals: DC+, DC-) for power terminal
DC bus undervoltage shutoff/fault 300V @ 600V
DC nominal bus voltage 900V @ 600V
DC power bus bar DC power from converter power module to inverter power module (2 terminals: DC+, DC-) for power terminal
Degree of protection (IP) IP00
Depth 1033 mm
Displacement power factor 0.98 across entire speed range.
Documentation English documentation set
Drive overcurrent trip Software overcurrent trip: 200% of rated current (typical)
Efficiency 97.5% at rated A, nominal line volts
Electronic motor overload protection Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Enclosure Type IP00/NEMA/UL Type open
Encoder duty cycle 50% ±10%
Encoder input voltage supply Dual channel plus marker, isolated with differential transmitter output (line drive) incremental, dual channel quadrature type 5V DC or 12V DC (5V DC requires an external power supply), 320 mA/channel for ftdback
Encoder quadrature 90°, ±27° at 25 °C
Encoder requirements Encoders must be line driver type, quadrature (dual channel) or pulse (single channel), 8...15V DC output (3.5...6V DC @ 5V encoder), single-ended or differential and capable of supplying a minimum of 10 mA per channel. Maximum input frequency is 250 kH
Encoder supply 12V @ 250mA. 12V @ 10mA minimum inputs isolated with differential transmitter, 250 kHz maximum
Encoder Type Incremental, dual channel
Equipment Type Inverter power module-stand alone version
Estimated amount of coolant 19 L
Feedback option No ftdback
Feedback Options No ftdback
Frequency accuracy Digital input: within ±0.01% of set output frequency
Frequency control Speed regulation with slip compensation (volts per Hz mode): 0.5% of base speed across 40:1 speed range 40:1 operating range 10 rad/sec bandwidth
Ground fault trip Phase-to-ground on drive output
Heat sink thermistor Monitored by microprocessor overtemp trip
Height 2278 mm mm
Human interface module LCD display full numeric keypad with progming keys
Input current rating 800A @ 810V DC
Input frequency tolerance 47...63 Hz
Input frequency, max 400 kHz ftdback
Input phases 3-phase input provides full rating for all drives.
Input power wire lugs Input power connections on drive (R/L1, S/L2, T/L3) for power terminal
Input Voltage 600V AC, 3-phase, 60 Hz
Intermittent overload 110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Internal Communication Module ControlNet coaxial
Lifecycle Status Discontinued
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Logic control ride-thru 0.5 s minimum, 2 s typical
Mains frequency 60 Hz
Mains voltage 600 V
Motor lead lengths 76 m (250 ft) total
Number of analogue inputs 2
Number of analogue outputs 2
Number of digital inputs 6
Number of digital outputs 3
Number of phases input 3
Number of phases output 3
Output current (with 600V AC induction motor) Normal duty: 885 A @ 110% of continuous current for 1 min
Output current rating 800A @ 870Hp (650 kW) normal duty, 640 Hp (480 kW) heavy duty, frame 3B
Output frequency 0 to 420 Hz
Output power bus bar Motor connections (U/T1, V/T2, W/T3) for power terminal
Output voltage range 0 to rated motor voltage
PE wire lug Terminating point for ground wires for power terminal
Pressure drop from drive inlet to drive outlet at minimum coolant flow rate 0.48 bar
PWM frequency 4 kHz
Recommended tightening torque 62 Nm (550 in-lb)(±10%), output power bus bar for power terminal
Recommended tightening torque for active converter cassette terminal blocks-P1 & P2 0.8 Nm (7 in-lb)(±10%) for control terminal
Recommended tightening torque for SHLD terminal 1.4 Nm (12 in-lb)(±10%) for control terminal
Recommended tightening torque for terminal blocks-TB5 and TB6 1.4 Nm (12 in-lb)(±10%) for control terminal
Relative Humidity 5...95% noncondensing
Repair Options Available Yes
Selectable motor control Sensorless vector with full tuning. Standard V/Hz with full custom capability and vector control with force technology (with and without ftdback).
SHLD terminal Terminating point for control wiring shields on power module for control terminal
Shock 10 G peak for 11 ms duration (±1.0 ms), three shocks in each direction, in each axis
Short circuit current rating To match specified circuit breaker capability, less than or equal to 200000 A symmetrical.
Short circuit trip Phase-to-phase on drive output
Shunt trip rating 35 kAIC @ 575...690V AC input voltage
Speed control Speed regulation with ftdback: 0.001% of base speed across 120:1 speed range 1000:1 operating range 250 rad/sec bandwidth
Stop modes Multiple progmable stop modes including RA, Coast, DC-brake, RA-to-hold and S-curve.
Storage Temperature -40...85 °C (-40...185 °F) for all constructions
Sub Brand PowerFlex 700L AC Drive
Supporting protocol for CAN true
Supporting protocol for DeviceNet true
Supporting protocol for EtherNet/IP true
Supporting protocol for Modbus true
Supporting protocol for PROFIBUS true
Supporting protocol for TCP/IP true
Surrounding air temperature without derating, max 0...40 °C (32...104 °F) @ IP20, NEMA/UL Type 1
Terminal blocks-TB5 and TB6 Power module control wiring for control terminal
Torque regulation with feedback ±2%, 2500 rad/sec bandwidth
Torque regulation without feedback ±5%, 600 rad/sec bandwidth
Vibration 2 mm (0.07 in.) displacement, 1 G peak Alitude, 1 mm (0.04 in.) displacement from 2…13.2 Hz, 0.7 G acceleration at 13.2 Hz to 1.0 G acceleration at 55 Hz, 1 G acceleration from 55 …512 Hz Duration: ten logarithmic sine sweep cycles per axis, at sweep ra
Watt loss Power section: 2400 W @ 400V into air
Weight 1361 kg
Width 1600 mm mm
Wire size 600 MCM to #2 AWG, PE wire lug for power terminal
Wire size for active converter cassette terminal blocks-P1 & P2 0.3 mm² to 3.3 mm² (#22 AWG to #12 AWG) for control terminal
Wire size for SHLD terminal 0.3 mm² to 2.1 mm² (#22 AWG to #14 AWG) for control terminal
Wire size for terminal blocks-TB5 and TB6 0.2 mm² to 4 mm² (#24 AWG to #10 AWG) for control terminal
Wire strip length for active converter cassette terminal blocks-P1 & P2 8 mm (0.31 in) for control terminal
Wire strip length for SHLD terminal 10 mm (0.39 in) for control terminal
Wire strip length for terminal blocks-TB5 and TB6 8 mm (0.31 in) for control terminal
With control element true

Frequently Asked Questions

How do I get pricing for 20LE800N3ENNKC20WA?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 20LE800N3ENNKC20WA?

20LE800N3ENNKC20WA is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 20LE800N3ENNKC20WA?

Key specifications include AC input overvoltage trip: 760V @ 600V; AC input undervoltage trip: 340V @ 600V; Acceleration/deceleration: Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments; Active converter cassette terminal blocks-P1 & P2: Active converter AC power and control wiring for control terminal. The full specification table on this page lists every published attribute for this part.

How quickly can 20LE800N3ENNKC20WA ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.