Allen-Bradley 140 A MCS D Safety Contactor 100S-D140EZY22C
Allen-Bradley 100S-D140EZY22C - IEC Safety Contactors - Contacts: 3 main poles with N.C. mechanically linked ftdback contacts; Weight: Non-reverse (Electronic-EI coil type): 3.8 kg @ DC; Ambient temperature: Storage: -40...80 °C.
Allen-Bradley 100S-D140EZY22C is a IEC Safety Contactors catalog item from Allen-Bradley. The manufacturer's published data for this part number specifies Contacts: 3 main poles with N.C. mechanically linked ftdback contacts and Weight: Non-reverse (Electronic-EI coil type): 3.8 kg @ DC.
Published specifications for this part include Ambient temperature: Storage: -40...80 °C; Lifecycle Status: Discontinued; Build America, Buy America: No; Repair Options Available: No; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: DC; Recommended torque: 88 to 106 in-lb; Switching frequency, max: 120 ops/h, AC-4 (approximately 200000 ops); Coil voltage: 48...72V DC electronic coil with electronic interface; Rated control supply voltage at DC: 48 V; Rated isolation voltage (Ui): 600V per UL, CSA; Protection class: IP00 IEC 60529/DIN 40050. See the Specifications tab on this page for the full technical table.
| Altitude of installation site, max | 2000 m (NN) per IEC 60947-4 |
|---|---|
| Ambient temperature | Storage: -40...80 °C |
| Auxiliary contact configuration | 2 NO, 2 NC auxiliary |
| Auxiliary contacts | IP20 IEC 60529/DIN 40050 |
| BS88 fuses current rating | Type2 (IEC 60947-4-1): 250A @ 415V, 65 kA available fault current |
| Build America, Buy America | No |
| Coil consumption, hold-in | Electronic coil: 6 W @ DC control |
| Coil consumption, pick-up | Electronic coil: 380VA @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil voltage | 48...72V DC electronic coil with electronic interface |
| Conductor cross-section | Top opening: 16 to 50 mm² |
| Contactor with frame terminal block | IP20 IEC 60529/DIN 40050 |
| Contacts | 3 main poles with N.C. mechanically linked ftdback contacts |
| Conventional coil type | true |
| Current (Ie), max | 140 A |
| Current rating | 115 A |
| DIN fuses (gG, gL) current rating | Type2 (IEC 60947-4-1): 250A @ 690V, 50 kA available fault current |
| Electronic-EI coil type | true |
| Features | Mirror contact performance on auxiliary contacts, which are required in ftdback circuit for modern safety applications, The NC auxiliary contacts will not change state when a power contact welds, SUVA third-party certification, AC and DC operating coils, |
| Frame terminal block conductor cross section | 3...9 mm @ s top |
| General purpose current (enclosed) | Load carrying capacity: 220 A per UL/CSA |
| Insulation class of the coil | Class B per VDE 0660, table 22 |
| Lifecycle Status | Discontinued |
| Lifespan | Mechanical DC control: 10000000 ops |
| Main contact terminal conductor cross section | 8.3 mm @ minimum Ø |
| Main current circuit resistance | 0.42 mΩ |
| Operating limits, dropout | Electronic coil: (0.3...0.5) x Us @ DC control |
| Operating limits, pick-up | (0.85...1.1) x Us @ DC control |
| Operating time, closing delay | Electronic coil: 35...110 ms @ DC |
| Operating time, opening delay | Electronic coil: 25...50 ms @ DC |
| Optional accessories | Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks |
| Power dissipation | 24.6 W @ 400V, AC-3, Ie |
| Protection against accidental contact | Finger and back-of-hand proof per VDE 0106, part 100 |
| Protection class | IP00 IEC 60529/DIN 40050 |
| Rated control supply voltage at DC | 48 V |
| Rated filament current | 140A @ 230/240V, AC-5b |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated isolation voltage (Ui) | 600V per UL, CSA |
| Rated operational current (Ie) | Electronic-EI coil type: 242A @ 690V, star-delta starting (50 Hz) |
| Rated operational current for contactor | 96A @ 460V, elevator duty (UL/CSA) |
| Rated operational power (Pe) | Electronic-EI coil type: 98 kW @ 500V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C |
| Rated power (enclosed) | 50Hp @ 230V, 3-phase per UL/CSA |
| Rated power for contactor | 75Hp @ 575V, elevator duty (UL/CSA) |
| Rating for switching AC motors | 82/90 kW @ 415V @ 50Hz, 3-phase (AC-2, AC-3) |
| Rating of group capacitors | 79 kVAR @ 1000V @ 50Hz, AC-6b, 60 °C |
| Rating of single capacitor | 73 kVAR @ 240V @ 50Hz, AC-6b, 40 °C |
| Recommended torque | 88 to 106 in-lb |
| Repair Options Available | No |
| Screw terminals | Thru-hole |
| Shock resistance | IEC 60068-2-27 |
| Short time withstand (Icw) | Electronic-EI coil type: 1360A @ 10s, 60 °C |
| Single contactor cover | IP10 IEC 60529/DIN 40050 |
| Switching frequency, max | 120 ops/h, AC-4 (approximately 200000 ops) |
| Switching of DC loads | 3-pole in series: 3.5A @ 440V (shunt-wound motors, starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
| Switching of hermetically sealed cooling compressor motors | 210A @ 690V, AC-8a (manual reset of overload release (50 Hz)) |
| Switching of lamps | Gas discharge lA, open: 225A @ 40°C, AC-5a |
| Switching of power transformers | Apparent power: 87.3 kVA @ 480V @ 60Hz |
| Total power dissipation | DC control (electronic coil): 30.6 W @ 400V, AC-3, Ie |
| Type of electrical connection of main circuit | Screw connection |
| UL class J and CSA HRCI-J fuses rating | Type2 (IEC60947-4-1): 250A @ 100kA available fault current per UL verified combination |
| UL class K5 and RK5 fuses rating | 350A @ 600V, 10 kA available fault current per UL listed combination |
| UL inverse-time circuit breaker | 200 A @ 600Y/347V @ 30kA available fault current per UL listed combination |
| Vibration resistance | IEC 60068-2-6 |
| Voltage type for actuating | DC |
| Weight | Non-reverse (Electronic-EI coil type): 3.8 kg @ DC |
Frequently Asked Questions
How do I get pricing for 100S-D140EZY22C?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 100S-D140EZY22C?
100S-D140EZY22C is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 100S-D140EZY22C?
Key specifications include Altitude of installation site, max: 2000 m (NN) per IEC 60947-4; Ambient temperature: Storage: -40...80 °C; Auxiliary contact configuration: 2 NO, 2 NC auxiliary; Auxiliary contacts: IP20 IEC 60529/DIN 40050. The full specification table on this page lists every published attribute for this part.
How quickly can 100S-D140EZY22C ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Allen-Bradley Allen-Bradley 630 A MCS D Safety Contactor 100S-D630EA22C
Allen-Bradley Allen-Bradley 43 A Safety Contactor 100S-C43UEJ14BC
Allen-Bradley Allen-Bradley IEC 12 A Safety Contactor 100S-E12KD23C
Allen-Bradley Allen-Bradley IEC 12 A Safety Contactor 100S-E12KJ14C
Allen-Bradley Allen-Bradley IEC 190 A Safety Contactor 100S-E190KD12C
Allen-Bradley
Industrial & MRO Parts