RTD Thermometer TR11
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Endress+Hauser RTD Thermometer TR11

Brand: Endress+Hauser SKU: TR11 Mfr Part #: TR11
Ships Same Day* Worldwide Shipping

Endress+Hauser TR11 - Temperature - Accuracy: class A acc. to IEC 60751 class AA acc. to IEC 60751; Response time: depending on configuration; Certification: Gost Metrology SIL (transmitter only) Marine approval.

In our catalog, the TR11 from Endress+Hauser is listed under the Temperature category. The manufacturer's published data for this part number specifies Accuracy: class A acc. to IEC 60751 class AA acc. to IEC 60751 and Response time: depending on configuration.

metric style modular temperature assembly universal range of application suitable for hazardous areas threaded process connection without neck incl. thermowell / protection tube (metal) can be used with StrongSens insert

Published specifications for this part include Certification: Gost Metrology SIL (transmitter only) Marine approval; Process Connection: male thread: G3/8" G1/2" G3/4" NPT1/2" NPT3/4" M20x1.5; Thermowell / protection tube: welded protection tube; Insert / probe: mineral insulated (MI), flexible; Max. immersion length on request: up to 10.000,00 mm (393,70''); Material protection tube/ thermowell: 1.4401 (316) 1.4404 (316L) 1.4571 (316Ti); Optional coating: Not defined; Tip shape: straight reduced tapered; Surface roughness Ra: Not defined; Max. process pressure (static): at 20 °C: 75 bar (1088 psi); Integration head transmitter: yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS). See the Specifications tab on this page for the full technical table.

Accuracy class A acc. to IEC 60751 class AA acc. to IEC 60751
Certification Gost Metrology SIL (transmitter only) Marine approval
Characteristic / Application metric style modular temperature assembly universal range of application suitable for hazardous areas threaded process connection without neck incl. thermowell / protection tube (metal) can be used with StrongSens insert
Ex - approvals ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6 ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6 ATEX IECEx II1/2D Ex ta/tb IIIC Da/Db ATEX II1G Ex ia IIC T6 ATEX II 3 G Ex nA IIC T6, II3D NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450 IECEx Ex ia IIC T6 Ga/Gb EAC Ex ia IIC T6 Ga + DIP NEPSI Ex nA IIC T6
Insert / probe mineral insulated (MI), flexible
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Material protection tube/ thermowell 1.4401 (316) 1.4404 (316L) 1.4571 (316Ti)
Max. immersion length on request up to 10.000,00 mm (393,70'')
Max. process pressure (static) at 20 °C: 75 bar (1088 psi)
Operating temperature range PT100 TF StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F)
Optional coating Not defined
Outer diameter protection tube / Insert 8,0 mm (0,31") 9,0 mm (0,35'') 11,0 mm (0,43'') 12,0 mm (0,47'') 14,0 mm (0,55") 15,0 mm (0,59")
Process Connection male thread: G3/8" G1/2" G3/4" NPT1/2" NPT3/4" M20x1.5
Response time depending on configuration
Surface roughness Ra Not defined
Thermowell / protection tube welded protection tube
Tip shape straight reduced tapered

Frequently Asked Questions

How do I get pricing for TR11?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the TR11?

TR11 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of TR11?

Key specifications include Accuracy: class A acc. to IEC 60751 class AA acc. to IEC 60751; Certification: Gost Metrology SIL (transmitter only) Marine approval; Characteristic / Application: metric style modular temperature assembly universal range of application suitable for hazardous areas threaded process connection without neck incl. thermowell / protection tube (metal) can be used with StrongSens insert; Ex - approvals: ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6 ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6 ATEX IECEx II1/2D Ex ta/tb IIIC Da/Db ATEX II1G Ex ia IIC T6 ATEX II 3 G Ex nA IIC T6, II3D NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450 IECEx Ex ia IIC T6 Ga/Gb EAC Ex ia IIC T6 Ga + DIP NEPSI Ex nA IIC T6. The full specification table on this page lists every published attribute for this part.

How quickly can TR11 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.