Endress+Hauser MEAC300 digital analyzer solution
| Ambient temperature range | +5 °C ... +40 °C |
|---|---|
| Calculations | 5s value, Average value, Daily average value, Monthly average value, Annual average value, Moving monthly average, Mass emissions, Daily mass emissions, Monthly mass emissions, Annual mass emissions, Daily counter, Monthly counter, Annual counter |
| Conformities | MEAC300 EP: EN 14181 (QAL2) 2010/75/EU (Annex V) MEAC300 EPW: EN 14181 (QAL2) 2010/75/EU (Annex V) 2010/75/EU (Annex VI) MEAC300 DE: EN 14181 (QAL2) BEP 2017 |
| I/O interfaces | Emission-PC: - Input: RS-232(-485)/Ethernet (Modbus RTU/TCP, VDI 4201-3) - Output: RS-232(-485)/Ethernet (Modbus RTU/TCP) DAU Data Acquisition Unit (option; including buffer memory): - Input: 80 analog (max.), 256 digital (max.) - Output: 32 analog (max.), 96 relays (max.) FM Field Module (option): - Input: 16 analog (max.), 32 digital (max.) - Output: 16 analog (max.), 24 digital (max.) |
| Measuring principle | Emission Data Acquisition and Handling |
| Software modules | Evaluation software variants (parameterization required) - “European Power”, version 4.0 - “European Power and Waste“, version 4.0 - “Germany CORE/PRIME/PRO“, version 4.2 Analog data acquisition software (Data acquisition unit (DAE) or field module (FM) required) Modbus RTU/TCP data acquisition software master and slave Remote access for remote PC (option) Central system software via TCP for central PC (option) Process image display software (Configuration required) Process display (option) Manual input (op |
Frequently Asked Questions
How do I get pricing for IMEAC30?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the IMEAC30?
IMEAC30 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of IMEAC30?
Key specifications include Ambient temperature range: +5 °C ... +40 °C; Calculations: 5s value, Average value, Daily average value, Monthly average value, Annual average value, Moving monthly average, Mass emissions, Daily mass emissions, Monthly mass emissions, Annual mass emissions, Daily counter, Monthly counter, Annual counter; Conformities: MEAC300 EP: EN 14181 (QAL2) 2010/75/EU (Annex V) MEAC300 EPW: EN 14181 (QAL2) 2010/75/EU (Annex V) 2010/75/EU (Annex VI) MEAC300 DE: EN 14181 (QAL2) BEP 2017; I/O interfaces: Emission-PC: - Input: RS-232(-485)/Ethernet (Modbus RTU/TCP, VDI 4201-3) - Output: RS-232(-485)/Ethernet (Modbus RTU/TCP) DAU Data Acquisition Unit (option; including buffer memory): - Input: 80 analog (max.), 256 digital (max.) - Output: 32 analog (max.), 96 relays (max.) FM Field Module (option): - Input: 16 analog (max.), 32 digital (max.) - Output: 16 analog (max.), 24 digital (max.). The full specification table on this page lists every published attribute for this part.
How quickly can IMEAC30 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Flow-X flow computer
Endress+Hauser Endress+Hauser HAW569 surge protective device
Endress+Hauser Endress+Hauser HAW568 surge protective device
Endress+Hauser Endress+Hauser HAW566 surge protective device
Endress+Hauser Endress+Hauser HAW562 surge protective devices
Endress+Hauser
Industrial & MRO Parts