Endress+Hauser MARSIC300 emission monitoring solution
Endress+Hauser IMAR300 - Optical analysis - Degree of protection: IP54; Measuring principle: NDIR spectroscopy; Process pressure: –20 hPa ... 200 hPa Relative.
This listing covers the Endress+Hauser IMAR300, a part number in the Optical analysis category. The manufacturer's published data for this part number specifies Degree of protection: IP54 and Measuring principle: NDIR spectroscopy.
CO2: 0 ... 25 Vol.-% SO2: 0 ... 30 ppm / 0 ... 2,000 ppm NO: 0 ... 300 ppm / 0 ... 2,000 ppm NO2: 0 ... 200 ppm / 0 ... 500 ppm CO: 0 ... 200 ppm / 0 ... 2,000 ppm NH3: 0 ... 50 ppm / 0 ... 500 ppm CH4: 0 ... 500 ppm / 0 ... 10,000 ppm H2O: 0 ... 40 Vol.-%
Key manufacturer data on file for this item includes Process pressure: –20 hPa ... 200 hPa Relative; Product safety: CE, Rules of major classification societies; Process temperature: +10 °C ... +550 °C; Measured variables: CO2, SO2, NO, NO2, CO, NH3, H2O, CH4; Ambient temperature range: 0 °C ... +50 °C Type approved up to 45 °C; Ambient humidity: ≤ 90 % Non-condensing. The complete technical table is shown in the Specifications tab on this page.
| Ambient humidity | ≤ 90 % Non-condensing |
|---|---|
| Ambient temperature range | 0 °C ... +50 °C Type approved up to 45 °C |
| Conformities | MARPOL Annex VI and NTC 2008 – MEPC.177(58) Guidelines for exhaust gas cleaning systems – MEPC.340(77) Guidelines for SCR reduction systems – MEPC.198(62) DNV Rules for Type Approvals (2012) IACS E10 and Rules of major classification societies |
| Degree of protection | IP54 |
| Measured variables | CO2, SO2, NO, NO2, CO, NH3, H2O, CH4 |
| Measuring principle | NDIR spectroscopy |
| Measuring range | CO2: 0 ... 25 Vol.-% SO2: 0 ... 30 ppm / 0 ... 2,000 ppm NO: 0 ... 300 ppm / 0 ... 2,000 ppm NO2: 0 ... 200 ppm / 0 ... 500 ppm CO: 0 ... 200 ppm / 0 ... 2,000 ppm NH3: 0 ... 50 ppm / 0 ... 500 ppm CH4: 0 ... 500 ppm / 0 ... 10,000 ppm H2O: 0 ... 40 Vol.-% |
| Process pressure | –20 hPa ... 200 hPa Relative |
| Process temperature | +10 °C ... +550 °C |
| Product safety | CE, Rules of major classification societies |
Frequently Asked Questions
How do I get pricing for IMAR300?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the IMAR300?
IMAR300 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of IMAR300?
Key specifications include Ambient humidity: ≤ 90 % Non-condensing; Ambient temperature range: 0 °C ... +50 °C Type approved up to 45 °C; Conformities: MARPOL Annex VI and NTC 2008 – MEPC.177(58) Guidelines for exhaust gas cleaning systems – MEPC.340(77) Guidelines for SCR reduction systems – MEPC.198(62) DNV Rules for Type Approvals (2012) IACS E10 and Rules of major classification societies; Degree of protection: IP54. The full specification table on this page lists every published attribute for this part.
How quickly can IMAR300 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser IMAR280
Endress+Hauser Endress+Hauser Maritime Suite digital analyzer solution
Endress+Hauser Endress+Hauser MCS100FT emission monitoring solution
Endress+Hauser Endress+Hauser HISIC450 overheight detector
Endress+Hauser Endress+Hauser MCS200HW emission monitoring solution
Endress+Hauser