Endress+Hauser FLOWSIC600-XT ultrasonic flowmeter
Endress+Hauser IFL6XT - Flow measurement - Repeatability: ≤ 0.05 % of the measured value (typical); Measuring principle: Ultrasonic transit time difference measurement; Operating Pressure Range: 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi.
This listing covers the Endress+Hauser IFL6XT, a part number in the Flow measurement category. The manufacturer's published data for this part number specifies Repeatability: ≤ 0.05 % of the measured value (typical) and Measuring principle: Ultrasonic transit time difference measurement.
4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated 4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench. 4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.
The specification set recorded for this part number covers Operating Pressure Range: 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g); Digital communication: Modbus TCP; Nominal pipe size: 3 ″ ... 56 ″ (DN 80 ... DN 1400), other nominal pipe sizes on request. See the Specifications tab on this page for the full technical table.
| Accuracy | 4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated 4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench. 4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench. |
|---|---|
| Digital communication | Modbus TCP |
| Digital outputs | 4 outputs: 2 x status, 2 x pulse: ≤ 30 V, 50 mA Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable) |
| Hazardous area approvals | IECEx Ex db ia op is [ia Ga] IIA/IIC T4 Gb Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb Ex ia op is IIA/IIC T4 Ga ATEX II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb II 1G Ex ia op is IIA/IIC T4 Ga NEC/CEC (US/CA) Explosion-proof / non-incendive: CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb Intrinsica |
| Measured variables | Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC) |
| Measuring Medium | Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2 |
| Measuring principle | Ultrasonic transit time difference measurement |
| Medium temperature range | –46 °C ... +180 °C / -51 °F ... +356 °F On request:–194 °C ... +280 °C / –381 °F ... +536 °F |
| Metrological approvals and certificates | OIML R 137-1&2:2012 (class 0.5) OIML D 11:2013 ISO 17089-1 AGA-Report Nr. 9 MID: 2014/32/EU PED: 2014/68/EU ASME: B16.5, B16.47 A/B ATEX: 2014/34/EU EMC: 2014/30/EU GOST 8.611-2013 GOST 8.733-2011 CPA: JJG1030-2007 PCEC: GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB/T 3836.22-2017 |
| Nominal pipe size | 3 ″ ... 56 ″ (DN 80 ... DN 1400), other nominal pipe sizes on request |
| Operating Pressure Range | 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g) |
| Repeatability | ≤ 0.05 % of the measured value (typical) |
Frequently Asked Questions
How do I get pricing for IFL6XT?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the IFL6XT?
IFL6XT is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of IFL6XT?
Key specifications include Accuracy: 4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated 4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench. 4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.; Digital communication: Modbus TCP; Digital outputs: 4 outputs: 2 x status, 2 x pulse: ≤ 30 V, 50 mA Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable); Hazardous area approvals: IECEx Ex db ia op is [ia Ga] IIA/IIC T4 Gb Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb Ex ia op is IIA/IIC T4 Ga ATEX II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb II 1G Ex ia op is IIA/IIC T4 Ga NEC/CEC (US/CA) Explosion-proof / non-incendive: CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb Intrinsica. The full specification table on this page lists every published attribute for this part.
How quickly can IFL6XT ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser FLOWSIC900 ultrasonic flowmeter
Endress+Hauser Endress+Hauser FLOWSIC600 DRU-S ultrasonic flowmeter
Endress+Hauser Endress+Hauser FLOWRUN flow metering system
Endress+Hauser Endress+Hauser FLOWSIC610ultrasonic flowmeter
Endress+Hauser Endress+Hauser FLOWSKID flow metering system
Endress+Hauser
Industrial & MRO Parts