Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
Micropilot S FMR530
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Endress+Hauser Micropilot S FMR530

Brand: Endress+Hauser SKU: FMR530 Mfr Part #: FMR530
Ships Same Day* Worldwide Shipping
Accuracy +/- 1 mm
Ambient temperature Standard: -40 °C ... 80 °C (-40 °F ... 176 °F) For calibration to regulatory standards: -25 °C ... 60 °C (-13 °F ... 131 °F)
Application Application
Application limits Application limits
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI
Communication 4 ... 20 mA HART
Frequency C-band (~6 GHz)
Main wetted parts 316Ti
Marine approval GL/ ABS
Max. measurement distance Max. measurement distance
Process Connection DN150 ... DN250 /3" ... 10"
Process pressure / max. overpressure limit Vacuum ... 64 bar (Vacuum ... 580 psi)
Process temperature -40 °C ... 200 °C (-40 °F ... 392 °F)
Safety approvals Overfill prevention WHG
Supply / Communication 4-wire (HART)

Frequently Asked Questions

How do I get pricing for FMR530?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the FMR530?

FMR530 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of FMR530?

Key specifications include Accuracy: +/- 1 mm; Ambient temperature: Standard: -40 °C ... 80 °C (-40 °F ... 176 °F) For calibration to regulatory standards: -25 °C ... 60 °C (-13 °F ... 131 °F); Application: Application; Application limits: Application limits. The full specification table on this page lists every published attribute for this part.

How quickly can FMR530 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.