Endress+Hauser CubemassCoriolis flowmeter
Endress+Hauser 8CM - Flow measurement - Degree of protection: IP67, type 4X enclosure; Power Supply: DC 10 to 30 V AC 20 to 28 V; Measuring range: 0 to 1000 kg/h (0 to 37 lb/min).
In our catalog, the 8CM from Endress+Hauser is listed under the Flow measurement category. The manufacturer's published data for this part number specifies Degree of protection: IP67, type 4X enclosure and Power Supply: DC 10 to 30 V AC 20 to 28 V.
Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases.
The specification set recorded for this part number covers Measuring range: 0 to 1000 kg/h (0 to 37 lb/min); Measuring principle: Coriolis; Outputs: Pulse/frequency/switch output (passive), phase‐shifted pulse; Nominal diameter range: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"); Display/Operation: No local operation Configuration via operating tools possible; Hazardous area approvals: ATEX, IECEx, NEC/CEC, NEPSI; Metrological approvals and certificates: 3.1 material; Wetted materials: Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L); Max. process pressure: PN 40, Class 300, 10K, 400 bar (5800 psi); Medium temperature range: –50 to +200 °C (–58 to +392 °F); Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F); Sensor housing material: 1.4301 (304), corrosion resistant. See the Specifications tab on this page for the full technical table.
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
|---|---|
| Degree of protection | IP67, type 4X enclosure |
| Digital communication | Modbus RS485 |
| Display/Operation | No local operation Configuration via operating tools possible |
| Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
| Inputs | None |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3 |
| Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Measuring principle | Coriolis |
| Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
| Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
| Metrological approvals and certificates | 3.1 material |
| Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR CRN |
| Outputs | Pulse/frequency/switch output (passive), phase‐shifted pulse |
| Power Supply | DC 10 to 30 V AC 20 to 28 V |
| Pressure approvals and certificates | CRN |
| Product headline | Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases. |
| Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter features | Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output. |
| Transmitter housing material | Powder‐coated die‐cast aluminium |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Frequently Asked Questions
How do I get pricing for 8CM?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 8CM?
8CM is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 8CM?
Key specifications include Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F); Degree of protection: IP67, type 4X enclosure; Digital communication: Modbus RS485; Display/Operation: No local operation Configuration via operating tools possible. The full specification table on this page lists every published attribute for this part.
How quickly can 8CM ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Proline Cubemass C 500Coriolis flowmeter
Endress+Hauser Endress+Hauser Cubemass DCICoriolis flowmeter
Endress+Hauser Endress+Hauser CNGmass DCICoriolis flowmeter
Endress+Hauser Endress+Hauser Proline Cubemass C 300Coriolis flowmeter
Endress+Hauser Endress+Hauser Proline Promass E 100 Coriolis flowmeter
Endress+Hauser
Industrial & MRO Parts