Endress+Hauser Proline t-mass T 150thermal mass flowmeter
Endress+Hauser 6TAB - Flow measurement - Degree of protection: IP66/67, type 4X enclosure; Power Supply: DC 18 to 30 V; Measuring range: 226 to 14 100 000 l/h (60 to 3 730 000 gal/h) (under reference conditions).
In our catalog, the 6TAB from Endress+Hauser is listed under the Flow measurement category. The manufacturer's published data for this part number specifies Degree of protection: IP66/67, type 4X enclosure and Power Supply: DC 18 to 30 V.
The flowmeter for reliable and easy monitoring of liquids. Dedicated to the monitoring of conductive and non‐conductive liquids.
The specification set recorded for this part number covers Measuring range: 226 to 14 100 000 l/h (60 to 3 730 000 gal/h) (under reference conditions); Measuring principle: Thermal; Outputs: 4‐20 mA HART (active) Pulse/frequency/switch output (passive); Nominal diameter range: DN 40 to 1000 (1½ to 40"); Hazardous area approvals: ATEX, IECEx, cCSAus, EAC; Material certificates: 3.1 material; Measured variables: Mass flow, temperature, volume flow; Max. measurement error: Flow: ±5 % o.f.s.; Max. process pressure: PN 40; Medium temperature range: –20 to +100 °C (–4 to +212 °F); Ambient temperature range: –40 to +60 °C (–40 to +140 °F); Transmitter housing material: AlSi10Mg, coated. See the Specifications tab on this page for the full technical table.
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
|---|---|
| Degree of protection | IP66/67, type 4X enclosure |
| Digital communication | HART |
| Display/Operation | 4‐line display with push buttons Configuration via local display and operating tools possible |
| Hazardous area approvals | ATEX, IECEx, cCSAus, EAC |
| Hygienic approvals and certificates | Sanitary approval: 3-A, EHEDG |
| Inputs | Status input |
| Material certificates | 3.1 material |
| Max. measurement error | Flow: ±5 % o.f.s. |
| Max. process pressure | PN 40 |
| Measured variables | Mass flow, temperature, volume flow |
| Measuring principle | Thermal |
| Measuring range | 226 to 14 100 000 l/h (60 to 3 730 000 gal/h) (under reference conditions) |
| Medium temperature range | –20 to +100 °C (–4 to +212 °F) |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Nominal diameter range | DN 40 to 1000 (1½ to 40") |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR Hygienic approvals: EHEDG, 3-A |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Power Supply | DC 18 to 30 V |
| Pressure approvals and certificates | CRN |
| Product headline | The flowmeter for reliable and easy monitoring of liquids. Dedicated to the monitoring of conductive and non‐conductive liquids. |
| Sensor features | High process safety – high repeatability and linearity due to integrated temperature compensation. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 40 to 1000 (1½ to 40"). Sensor in standard or hygienic version. |
| Transmitter features | Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output. |
| Transmitter housing material | AlSi10Mg, coated |
| Wetted materials | Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: ‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) ‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) ‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) ‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L) |
Frequently Asked Questions
How do I get pricing for 6TAB?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 6TAB?
6TAB is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 6TAB?
Key specifications include Ambient temperature range: –40 to +60 °C (–40 to +140 °F); Degree of protection: IP66/67, type 4X enclosure; Digital communication: HART; Display/Operation: 4‐line display with push buttons Configuration via local display and operating tools possible. The full specification table on this page lists every published attribute for this part.
How quickly can 6TAB ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Proline t-mass I 500thermal mass flowmeter
Endress+Hauser Endress+Hauser Proline Prowirl D 200vortex flowmeter
Endress+Hauser Endress+Hauser Proline t-mass I 300thermal mass flowmeter
Endress+Hauser Endress+Hauser Proline Prowirl F 200vortex flowmeter
Endress+Hauser Endress+Hauser Proline t-mass F 500thermal mass flowmeter
Endress+Hauser
Industrial & MRO Parts