Danfoss IC7-60SAIN05-1710E00F4+AE10+AKFX+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL15+CAX0+DA
| AC voltage | 3X0-400/460/500VAC |
|---|---|
| Additional drive features 1 | +DD1X |
| Additional drive features 2 | +DE2X |
| Additional drive features 3 | +DF3X |
| Additional drive features 4 | +DG4X |
| Additional drive features 5 | +DH5X |
| Calculated Gross Weight [kg] | 264 |
| Calculated Net Weight [kg] | 204 |
| check if complete | OK |
| Communication interface, X0 | +BBEL |
| Communication interface, X1/X2 | +BAMT |
| Continous current IH (1/5min) | 1420A(400VAC)/1310A(460VAC) |
| Continous current IL (1/5min) | 1710A(400VAC)/1570A(460VAC) |
| Control panel | +BF20 |
| Control panel cable length | +BH15 |
| Control panel mounting type | +BGK1 |
| Control unit cable length | +BK03 |
| Cooling circuit connector type | +ANXX |
| Cooling circuit hose length | +AOXX |
| Cooling type | Air Cooled |
| Current rating | -1710 |
| Customer specific application | +DBXX |
| Customer-specific label | +EJXX |
| Customization file package ID | +EAXXXXXX |
| DC Bus current | 1826A(540VDC) |
| DC Bus voltage | 465-740VDC |
| DC fuses and devices | +AKFX |
| DC power | 986kW(540VDC) |
| Documentation language | +EHEN |
| EAN | 5715253279220 |
| ECCN EU | Y901 |
| ECCN US | 3A999.a |
| EMC Category | F4 |
| Enclosure rating | IP00 / OPEN TYPE |
| Extra environmental protection | +AGCX |
| Frame Designation | 2XIR11 |
| Functional safety | +BEXX |
| Gross weight | 264 Kilogram |
| Help Counter | 1 |
| High Speed Drive Warning | NONE |
| High speed enabled | +DI6X |
| Integration unit | +AE10 |
| Language package | +EL01 |
| Main unit Depth | 553mm/21.8in |
| Main unit Height | 1530mm/60.2in |
| Main unit Width | 2x235mm/9.3in |
| Mains input device | +AJXX |
| Mains voltage | 05 |
| Marine construction | +AFXX |
| Modelcode01 | IC7-60SAIN05-1710E00F4 |
| Modelcode02 | +AE10+AKFX |
| Modelcode03 | +BAMT+BDC1+BEXX+BF20 |
| Modelcode04 | +BGK1+BH15+BK03+BL15+CAX0 |
| Modelcode06 | +DAAU |
| Modelcode08 | +EGIN+EHEN |
| Net weight | 204 Kilogram |
| Nominal AC current | 1746A(400VAC)/1603A(460VAC) |
| Option Slot A | +CAX0 |
| Option Slot B | +CBXX |
| Option Slot C | +CCXX |
| Option Slot D | +CDXX |
| Option Slot E | +CEXX |
| Option slot F | +CFXX |
| Option slot G | +CGXX |
| Option slot H | +CHXX |
| Option slot I | +CIXX |
| Option slot J | +CJXX |
| Output frequency | 0-590Hz |
| Overload current IH (1/5min) | 2130A(400VAC)/1965A(460VAC) |
| Overload current IL (1/5min) | 1881A(400VAC)/1727A(460VAC) |
| Power Rating | 900 |
| Product Catalog | NO_VIEW |
| Product category | SA |
| Product Category -DrivesSymbol | System module, air-cooled |
| Product group | IC7-60 |
| Product Series | +DAAU |
| Product software ID | +ECXXX |
| Product specific marine cert. | +VBXX |
| Product type | IN |
| Product Type - DrivesSymbol | Inverter module |
| Product View (Switch) | GLBL |
| Protection Rating | E00 |
| Recommended Plant | ERR01 |
| Salescode part 1 | IC7-60SAIN05-1710E00F4 |
| Salescode part 2 | +AE10+AKFX |
| Salescode part 3 | +BAMT+BDC1+BEXX+BF20 |
| Salescode part 4 | +BGK1+BH15+BK03+BL15+CAX0 |
| Salescode part 5 | +DAAU |
| Salescode part 6 | +EGIN+EHEN |
| Shipping package | +TACB |
| Short circuit current rating | 100kA |
| Standard I/O | +BDC1 |
| StarCoupler board cable length | +BL15 |
| Start current Imax (3sec) | 2414A |
| Storage Temperature | -40...70°C/-40...158°F |
| Technical documentation | +EGIN |
| Typecode Part 1 | 7SM-AUSAIN05-1710E00F4 |
| Typecode Part 2 | -000096513 |
| Typical motor power PH2 (150%) | 710kW(400VAC)/1100Hp(460VAC) |
| Typical motor power PL (110%) | 900kW(400VAC)/1300Hp(460VAC) |
| Vendor | ERR01 |
| Volume | 1508 Liter |
Frequently Asked Questions
How do I get pricing for 137G1991?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 137G1991?
137G1991 is a Danfoss part. KKM Solutions sources Danfoss components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 137G1991?
Key specifications include AC voltage: 3X0-400/460/500VAC; Additional drive features 1: +DD1X; Additional drive features 2: +DE2X; Additional drive features 3: +DF3X. The full specification table on this page lists every published attribute for this part.
How quickly can 137G1991 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Danfoss Danfoss IC7-60SA3A05-1630E00F3+AE10+AJFX+AKFX+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL15+CA
Danfoss Danfoss IC7-60SA3A05-816AE00F3+AE10+AJFX+AKFX+BAMT+BDC1+BEXX+BF20+BGK1+BH50+BK50+CAX0+DA
Danfoss Danfoss IC7-60SA3A05-1210E00F3+BD00+BEXX+BF20+DAAU+EGIN+EHEN
Danfoss Danfoss IC7-60SAIN05-1100E00F4+AKFX+BD00+BEXX+BF20+DAAU+EGIN+EHEN
Danfoss Danfoss IC7-60SA3A05-1210E00F3+AKFX+BAMT+BD00+BEXX+BF20+DAAU+EGIN+EHEN
Danfoss
Industrial & MRO Parts