Allen-Bradley 284E-FVD2P3Z-10-CRN-3-OC - industrial components - Operating Temperature: -20 °C; Lifecycle Status: Discontinued; Build America, Buy America: No.
The Allen-Bradley 284E-FVD2P3Z-10-CRN-3-OC is part of the industrial components range in our industrial catalog. The manufacturer's published data for this part number specifies Operating Temperature: -20 °C and Lifecycle Status: Discontinued.
The specification set recorded for this part number covers Build America, Buy America: No; Repair Options Available: Yes; Enclosure Type: IP67/NEMA 4; Degree of protection (IP): IP67; Degree of protection (NEMA): 4; Altitude: 1000 m; Number of poles: 3; Trip Class: Class 10; Tightening torque: Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal); Depth, approx: 266.9 mm @ 460V AC, conduit entrance, 2 Hp and below; Height, approx: 287.5 mm @ 460V AC, conduit entrance, 2 Hp and below; Mains frequency: 50/60 Hz. See the Specifications tab on this page for the full technical table.
| 3-phase power/motor cable connection | Conduit entrance with motor cable |
|---|---|
| Altitude | 1000 m |
| Application in industrial area permitted (SCPD list) | Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
| Approximate shipping weight | 19.1 kg |
| Baud rates | 125, 250, 500 kbps |
| Build America, Buy America | No |
| Communication | EtherNet/IP |
| Conducted radio frequency emissions | Class A |
| Connection type | Quick disconnects |
| Conventional thermal current (Ith) | Output rating- sourced from control circuit: total of both outputs ≤2 A |
| Current available | Sensor source: 50 mA maximum per input, 200 mA total |
| Degree of protection (IP) | IP67 |
| Degree of protection (NEMA) | 4 |
| Depth, approx | 266.9 mm @ 460V AC, conduit entrance, 2 Hp and below |
| DeviceNet input current | 364mA @ 11V DC - 4.0 W |
| DeviceNet input current surge | 15 A for 250 µs |
| DeviceNet supply voltage rating | Range 11...25V DC @ 24V DC Nominal |
| Dielectric withstand | Power circuit: 2500V AC per IEC |
| Disconnect | Motor disconnect |
| Disconnect lock out | Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed. |
| Distance, max | 500 m (1630 ft) @ 125 kbps |
| Drive input current ratings | 3.80A @ 380V, 0.75 kW, 3-phase, 50 Hz |
| Electrostatic discharge | 4 kV contact and 8 kV air |
| Enclosure Type | IP67/NEMA 4 |
| External devices powered by DeviceNet | 50 mA - total 200 mA |
| Fast transient | 2 kV |
| Height, approx | 287.5 mm @ 460V AC, conduit entrance, 2 Hp and below |
| Humidity | 5...95% on-condensing |
| Input compatibility | IEC 1133 Type 1+ |
| Input filter - software selectable | ON to OFF: settable from 0…64 ms in 1 ms increments |
| Input OFF-state current | <1.5 mA |
| Input OFF-state voltage | 0...5V DC |
| Input ON-state current | 7.2mA @ 24V DC |
| Input ON-state voltage | 10...26V DC |
| Insulation voltage | Power circuit: rated 600V AC |
| Kind of current | Output rating- sourced from control circuit: AC/DC |
| Lifecycle Status | Discontinued |
| Mains frequency | 50/60 Hz |
| Max. output frequency | 400 Hz |
| Nominal control power (hold in) | External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor |
| Nominal control power (pick up) | External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor |
| Number of analogue inputs | 4 |
| Number of contacts | Output rating- sourced from control circuit: 2 |
| Number of digital inputs | 4 |
| Number of digital outputs | 2 |
| Number of inputs | 4 |
| Number of poles | 3 |
| Operating frequency | Power circuit: 50/60 Hz |
| Operating Temperature | -20 °C |
| Option 1 | HAND-OFF-AUTO selector keypad with jog function |
| Option 3 | Output contactor |
| Outputs current (2) 1 A each, max | External devices powered by control voltage: 2 A @ with brake and output contactor |
| Overload protection | I²t overload protection - 150% @ 60s, 200% @ 30s |
| Overvoltage category | Control circuit: III per IEC |
| Pollution degree | 3 |
| Product type | AC Drive |
| Protection against shock | Power circuit: IP2X per IEC |
| Radiated emissions | Class A, group 1, equivalent to C2 emissions |
| Radio frequency electromagnetic field | 10 V/m |
| Rated impulse voltage | Power circuit: rated 6 kV |
| Rated input operation voltage | 24V DC |
| Rated operation voltage | Power circuit: 380Y/220...480Y/277V AC |
| Rated output operating current, max | Power circuit: 2.3 A @ 3-phase, 1 Hp rating |
| Rated output operation voltage | Sourced from control circuit: 240V AC / 30V DC |
| Repair Options Available | Yes |
| RMS symmetrical amperes | 65kA @ 480V/277V per UL/NEMA |
| Shock | opsal: 15 G |
| Short circuit protection | 10 A rated device |
| Short-circuit protection device list | Size per NEC group motor per UL/NEMA |
| Storage and transportation temperature | -25 °C |
| Supporting protocol for EtherNet/IP | true |
| Surge transient | 1 kV L-L, 2 kV L-N (earth) |
| Terminal wire size | Control and safety monitor inputs: 1.0...4.0 mm² per IEC |
| Tightening torque | Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal) |
| Torque Performance | Sensorless Vect Ctrl and V/Hz |
| Torque performance mode | Sensorless vector control and volts per Hz |
| Total w/max. sensor inputs (4) | 367mA @ 24V DC - 8.0 W |
| Trip Class | Class 10 |
| Type of contacts | Output rating- sourced from control circuit: normally open (NO) |
| Type of control circuit | Output rating- sourced from control circuit: electromechanical relay |
| Utilization category | Power circuit: AC-3 per IEC |
| Vibration | opsal, 1 G, 0.15 mm (0.006 in) displacement |
| Voltage status | Sensor source: 11...25V DC from DeviceNet |
| Width, approx | 420.38 mm @ 460V AC, conduit entrance, 2 Hp and below |
| Wire size | Power and ground terminals: 1.5...4.0 mm² per IEC (primary/sary terminal) |
| Wire strip length | Power and ground terminals: 9 mm (0.35 in) |
Frequently Asked Questions
How do I get pricing for 284E-FVD2P3Z-10-CRN-3-OC?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 284E-FVD2P3Z-10-CRN-3-OC?
284E-FVD2P3Z-10-CRN-3-OC is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 284E-FVD2P3Z-10-CRN-3-OC?
Key specifications include 3-phase power/motor cable connection: Conduit entrance with motor cable; Altitude: 1000 m; Application in industrial area permitted (SCPD list): Size per NFPA 70 (NEC) or NFPA 79 for group motor applications; Approximate shipping weight: 19.1 kg. The full specification table on this page lists every published attribute for this part.
How quickly can 284E-FVD2P3Z-10-CRN-3-OC ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Allen-Bradley Allen-Bradley EtherNet_IP ArmorStart VFD - Safety 284E-FVD2P3S-10-RRG-SBG-DB1-EMI
Allen-Bradley Allen-Bradley EtherNet_IP ArmorStart VFD Safety 284E-FVD2P3Z-10-CRW-3-DBW-SBW
Allen-Bradley Allen-Bradley EtherNet_IP ArmorStart VFD 284E-FVD2P3Z-10-CRW-3-OC
Allen-Bradley Allen-Bradley EtherNet_IP ArmorStart VFD Safety 284E-FVD1P4Z-10-CR
Allen-Bradley Allen-Bradley EtherNet_IP ArmorStart VFD 284E-FVD2P3Z-10-CRW-3
Allen-Bradley
Industrial & MRO Parts