Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
284D-FVD2P3Z-10-RR-DB
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley DeviceNet ArmorStart VFD Safety 284D-FVD2P3Z-10-RR-DB

Brand: Allen-Bradley SKU: 284D-FVD2P3Z-10-RR-DB
Ships Same Day* Worldwide Shipping

Allen-Bradley 284D-FVD2P3Z-10-RR-DB - industrial components - Operating Temperature: -20 °C; Lifecycle Status: Discontinued; Build America, Buy America: No.

The Allen-Bradley 284D-FVD2P3Z-10-RR-DB is part of the industrial components range in our industrial catalog. The manufacturer's published data for this part number specifies Operating Temperature: -20 °C and Lifecycle Status: Discontinued.

Key manufacturer data on file for this item includes Build America, Buy America: No; Repair Options Available: Yes; Degree of protection (IP): IP67; Degree of protection (NEMA): 4; Altitude: 1000 m; Number of poles: 3; Trip Class: Class 10; Tightening torque: Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal); Application in industrial area permitted: true; Carrier frequency: Sensorless vector control: 2...16 kHz. drive rating is based on 4 kHz.; Mains frequency: 50/60 Hz; Number of digital inputs: 4. The complete technical table is shown in the Specifications tab on this page.

3-phase power/motor cable connection ArmorConnect power media connectivity with motor cable
Accel/decel Sensorless vector control: two independently progmable accel and decel times. Each time may be progmed from 0...600 s in 0.1 s increments.
Altitude 1000 m
Application in industrial area permitted true
Application in industrial area permitted (SCPD list) Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Approximate shipping weight 19.1 kg
Baud rates 125, 250, 500 kbps
Build America, Buy America No
Carrier frequency Sensorless vector control: 2...16 kHz. drive rating is based on 4 kHz.
Communication DeviceNet
Communications DeviceNet
Conducted radio frequency emissions Class A
Connection type Quick disconnects
Conventional thermal current (Ith) Output rating- sourced from control circuit: total of both outputs ≤2 A
Current available Sensor source: 50 mA maximum per input, 200 mA total
DB resistance, min 97 Ω @ drive input voltage of 480V @ 50/60Hz, 3-phase, 2.2 kW, 3 Hp
Degree of protection (IP) IP67
Degree of protection (NEMA) 4
DeviceNet input current 364mA @ 11V DC - 4.0 W
DeviceNet input current surge 15 A for 250 µs
DeviceNet supply voltage rating Range 11...25V DC @ 24V DC nominal
Dielectric withstand Power circuit: 2500V AC per IEC
Disconnect Motor disconnect
Disconnect lock out Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Distance, max 500 m (1630 ft) @ 125 kbps
Drive efficiency 97.5% Typical
Drive input current ratings 3.80A @ 380V, 0.75 kW, 3-phase, 50 Hz
Drive output current ratings 2.3A @ 460V, 1 Hp, 3-phase, 60 Hz
Drive output frequency 0...400 Hz Progmable
Electronic motor overload protection Sensorless vector control: class 10 protection with speed sensitive response
Electrostatic discharge 4 kV contact and 8 kV air
External devices powered by DeviceNet 50 mA - total 200 mA
Fast transient 2 kV
Frequency accuracy - digital input Sensorless vector control: within ±0.05% of set output frequency.
Hp (KW) rating/input voltage, max Sensorless vector control: 5 Hp (3.3 kW)/480V AC
Humidity, max 5...95% on-condensing
Input compatibility IEC 1133 Type 1+
Input filter - software selectable ON to OFF: settable from 0…64 ms in 1 ms increments
Input OFF-state current <1.5 mA
Input OFF-state voltage 0...5V DC
Input ON-state current 7.2mA @ 24V DC
Input ON-state voltage 10...26V DC
Insulation voltage Power circuit: rated 600V AC
Internal fan Fan L10 ops data: 80K hours at 40 °C and 98K hours at 25 °C (77 °F) ambient
Kind of current Output rating- sourced from control circuit: AC/DC
Lifecycle Status Discontinued
Mains frequency 50/60 Hz
Max. output frequency 400 Hz
Nominal control power (hold in) External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor
Nominal control power (pick up) External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor
Number of contacts Output rating- sourced from control circuit: 2
Number of digital inputs 4
Number of digital outputs 2
Number of poles 3
Operating frequency Power circuit: 50/60 Hz
Operating Temperature -20 °C
Operational power rating Volts per Hz (SVP) performance - IP67/NEMA Type 4: 5Hp @ 380...480V, 50/60 Hz, 3 phase (DeviceNet communication)
Option 2 DB brake connector
Outputs current (2) 1 A each, max External devices powered by control voltage: 2 A @ with brake and output contactor
Overload protection I²t overload protection - 150% @ 60s, 200% @ 30s
Overvoltage category Control circuit: III per IEC
Pollution degree 3
Preset speeds Sensorless vector control: 8
Product type AC Drive
Protection against shock Power circuit: IP2X per IEC
Radiated emissions Class A, group 1, equivalent to C2 emissions
Radio frequency electromagnetic field 10 V/m
Rated impulse voltage Power circuit: rated 6 kV
Rated input operation voltage 24V DC
Rated operation voltage Power circuit: 380Y/220...480Y/277V AC
Rated output operating current, max Power circuit: 2.3 A @ 3-phase, 1 Hp rating
Rated output operation voltage Sourced from control circuit: 240V AC / 30V DC
Repair Options Available Yes
RMS symmetrical amperes 65kA @ 480V/277V per UL/NEMA
Shock opsal: 15 G
Short circuit protection 10 A rated device
Short-circuit protection device list Size per NEC group motor per UL/NEMA
Skip frequency Sensorless vector control: Yes
Speed regulation - open loop with slip compensation Sensorless vector control: ±1% of base speed across a 60:1 speed range
StepLogic® functionality Sensorless vector control: Yes
Stop modes Sensorless vector control: multiple progmable stop modes including - rA, coast, DC-brake, rA-to-hold and S curve.
Storage and transportation temperature -25 °C
Supporting protocol for DeviceNet true
Surge transient 1 kV L-L, 2 kV L-N (earth)
Terminal wire size Control and safety monitor inputs: 1.0...4.0 mm² per IEC
Tightening torque Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Timer/counter functions Sensorless vector control: Yes
Torque performance mode Sensorless vector control and volts per Hz
Total w/max. sensor inputs (4) 367mA @ 24V DC - 8.8 W
Trip Class Class 10
Type of contacts Output rating- sourced from control circuit: normally open (NO)
Type of control circuit Output rating- sourced from control circuit: electromechanical relay
Utilization category Power circuit: AC-3 per IEC
Vibration opsal, 1 G, 0.15 mm (0.006 in) displacement
Voltage status Sensor source: 11...25V DC from DeviceNet
Wire size Power and ground terminals: 1.5...4.0 mm² per IEC (primary/sary terminal)
Wire strip length Power and ground terminals: 9 mm (0.35 in)

Frequently Asked Questions

How do I get pricing for 284D-FVD2P3Z-10-RR-DB?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 284D-FVD2P3Z-10-RR-DB?

284D-FVD2P3Z-10-RR-DB is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 284D-FVD2P3Z-10-RR-DB?

Key specifications include 3-phase power/motor cable connection: ArmorConnect power media connectivity with motor cable; Accel/decel: Sensorless vector control: two independently progmable accel and decel times. Each time may be progmed from 0...600 s in 0.1 s increments.; Altitude: 1000 m; Application in industrial area permitted: true. The full specification table on this page lists every published attribute for this part.

How quickly can 284D-FVD2P3Z-10-RR-DB ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products