Allen-Bradley ArmorStart Reversing Starter 281D-F12D-10C-CR
Allen-Bradley 281D-F12D-10C-CR - industrial components - Operating Temperature: -20 °C; Lifecycle Status: Discontinued; Build America, Buy America: No.
Allen-Bradley 281D-F12D-10C-CR is a industrial components catalog item from Allen-Bradley. The manufacturer's published data for this part number specifies Operating Temperature: -20 °C and Lifecycle Status: Discontinued.
Key manufacturer data on file for this item includes Build America, Buy America: No; Repair Options Available: No; Degree of protection (IP): IP67; Degree of protection (NEMA): 4; Altitude: 2000 m; Electrical life cycle: Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr); Mechanical life operations: Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr); Number of poles: 3; Shipping weight, approx: 10.4 kg; Trip Class: Class 10, 15, 20; Tightening torque: Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal); Application in industrial area permitted: true. The complete technical table is shown in the Specifications tab on this page.
| 3-phase power/motor cable connection | Conduit entrance with motor cable |
|---|---|
| Altitude | 2000 m |
| Application in industrial area permitted | true |
| Application in industrial area permitted (SCPD list) | Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
| Baud rates | 500 kbps |
| Build America, Buy America | No |
| Circuit breaker operational current rating, max | 60A @ 480V (with gland type: CR or DR) |
| Communication | DeviceNet |
| Conducted radio frequency emissions | Class A |
| Connection type | Quick disconnects |
| Control (hold in) | Power requirements: 0.075 A without HOA |
| Control (pick up) | Power requirements: 0.583 A without HOA |
| Conventional thermal current (Ith) | Output rating- sourced from control circuit: total of both outputs ≤2 A |
| Current available | 50 mA maximum per input, 200 mA total |
| Degree of protection (IP) | IP67 |
| Degree of protection (NEMA) | 4 |
| Depth, approx | Motor connection 243 mm (9.57 in) M35 cordset |
| DeviceNet input current | 364mA @ 11V DC - 4.0 W |
| DeviceNet input current surge | 15 A for 250 µs |
| DeviceNet supply voltage rating | 24V DC nominal |
| Dielectric withstand | Power circuit: 2500V AC per IEC |
| Disconnect | Motor disconnect |
| Disconnect lock out | Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed. |
| Distance, max | 500 m (1630 ft) @ 125 kbps |
| Electrical life cycle | Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr) |
| Electrostatic discharge | 4 kV contact and 8 kV air |
| External devices powered by DeviceNet | 50 mA - total 200 mA |
| Fast transient | 2 kV |
| Fuse operational current rating, max | Time delay: 20 A @ 480Y/277V (with gland type: RR) |
| Height, approx | 287.5 mm |
| Humidity | 5...95% (noncondensing) |
| Input compatibility | IEC 1133 Type 1+ per IEC |
| Input filter - software selectable | Settable from 0...64 ms in 1 ms increments (ON to OFF) |
| Input OFF-state current | <1.5 mA |
| Input OFF-state voltage | 0...5V DC |
| Input ON-state current | 7.2mA @ 24V DC |
| Input ON-state voltage | 10...26V DC |
| Insulation voltage | Power circuit: rated 600V |
| Kind of current | Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply) |
| Lifecycle Status | Discontinued |
| Mains frequency | 50/60 Hz |
| Mechanical life operations | Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr) |
| Number of contacts | Output rating- sourced from control circuit: 2 |
| Number of digital inputs | 4 |
| Number of digital outputs | 2 |
| Number of poles | 3 |
| Operating frequency | Power circuit: 50/60 Hz |
| Operating Temperature | -20 °C |
| Operational power rating | Reversing starters - IP67/Type 4/12: 3Hp @ 575V AC, 60 Hz |
| Option 1 | Status only keypad |
| Outputs current (2) 1 A max. each | External devices powered by control voltage: 2 A without HOA |
| Overload selection current range | 1.1 A |
| Overvoltage category | Control circuit: III per IEC |
| Pollution degree | 3 |
| Product type | Reversing starter |
| Protection against shock | Power circuit: IP2X per IEC |
| Radiated emissions | Class A, Group 1, equivalent to C2 emissions |
| Radio frequency electromagnetic field | 10 V/m |
| Rated impulse voltage | Power circuit: 6 kV |
| Rated operation voltage | Power circuit: 200...575V |
| Rated operational current | Power circuit: 5.5 A maximum |
| Rated output operation voltage | Sourced from control circuit: 30V DC |
| Repair Options Available | No |
| RMS symmetrical amperes | 65 kA @ 480Y/277V (with gland type: RR) |
| Shipping weight, approx | 10.4 kg |
| Shock | opsal: 15 G |
| Short circuit protection | 10 A rated device |
| Short circuit protection device performance (SCPD) type | Type 1 |
| Short circuit rating | 30 kA |
| Storage and transportation temperature | -25 °C |
| Supporting protocol for DeviceNet | true |
| Surge transient | 1 kV L-L, 2 kV L-N (earth) |
| Tightening torque | Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal) |
| Total control power (hold in) | Power requirements: 9VA without HOA |
| Total control power (hold in) with max outputs | External devices powered by control voltage: 275VA with HOA |
| Total control power (pick up) | Power requirements: 83VA with HOA |
| Total control power (pick up) with max outputs | External devices powered by control voltage: 336VA with HOA |
| Total with maximum sensor inputs (4) | 367mA @ 24V DC - 8.8 W |
| Trip Class | Class 10, 15, 20 |
| Trip rating | 120% of full load current (FLC) setting |
| Type of contacts | Output rating- sourced from control circuit: normally open (NO) |
| Type of control circuit | Output rating- sourced from control circuit: electromechanical relay |
| Utilization category | Power circuit: AC-3 per IEC |
| Vibration | opsal, 1 G, 0.15 mm (0.006 in) displacement |
| Voltage status only | 11...25V DC from DeviceNet |
| Width, approx | 351 mm |
| Wire size | Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal) |
| Wire strip length | Power and ground terminals: 0.35 in (9 mm) |
Frequently Asked Questions
How do I get pricing for 281D-F12D-10C-CR?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 281D-F12D-10C-CR?
281D-F12D-10C-CR is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 281D-F12D-10C-CR?
Key specifications include 3-phase power/motor cable connection: Conduit entrance with motor cable; Altitude: 2000 m; Application in industrial area permitted: true; Application in industrial area permitted (SCPD list): Size per NFPA 70 (NEC) or NFPA 79 for group motor applications. The full specification table on this page lists every published attribute for this part.
How quickly can 281D-F12D-10C-CR ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Allen-Bradley Allen-Bradley ArmorStart Reversing Starter 281D-F12D-10C-CR-3FR-SM
Allen-Bradley Allen-Bradley ArmorStart Reversing Starter 281D-F12D-10C-RR
Allen-Bradley Allen-Bradley ArmorStart Reversing Starter 281D-F12D-10B-CR-3FR-SM
Allen-Bradley Allen-Bradley DeviceNet ArmorStart VFD Safety 284D-FVD2P3D-10-CR-3-SB-OC
Allen-Bradley Allen-Bradley ArmorStart Repair Base Mod Starter 280E-FN-10-C
Allen-Bradley
Industrial & MRO Parts