Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
20DC5P0A0EYNANCNK
Request a Quote Email orderdesk@kkmsolutions.com for pricing and availability.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley PowerFlex 700S AC Drive 20D 20DC5P0A0EYNANCNK

Brand: Allen-Bradley SKU: 20DC5P0A0EYNANCNK
Ships Same Day* Worldwide Shipping
AC input overvoltage trip 600V AC @ 380/400V (six pulse, 3-phase)
Acceleration/deceleration Independently progmable accel and decel times adjustable from 0 to 6553.5 in 0.1 s increments
Additional configuration Phase II DriveLogix 5730
Altitude 1000 m (3300 ft.) maximum without derating
Atmosphere Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
Battery 1769-BA 0.59 g lithium
Brake IGBT Brake IGBT installed
Brake Resistor No internal brake resistor
Build America, Buy America No
Cable 20D-DL2-CL3, 20D-DL2-CR3
Carrier frequency Drive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz ops only)
Circuit breaker current rating, max 20A @ 400V AC, 3-phase
Compact I/O configuration Up to (16) modules (8 modules per bank or 4 max on either side of the power supply)
Control logic noise immunity Showering arc transients upto 1500V peak
Control method Induction motor and brushless motor: sine coded PWM with progmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
Control options Phase II control with logix expansion board, expanded cassette
Current limit capability Independent motoring and regenerative power limits progmable to 800% of rated output current
DC bus overvoltage trip 810V DC @ 380/400V
DC bus undervoltage trip Adjustable
DC nominal bus voltage 540V DC @ 380/400V
Degree of protection (IP) IP20
Degree of protection (NEMA) 1
Depth, approx 200 mm
Displacement power factor 0.98 across speed range
Documentation English documentation
Drive full power range 383...528V @ 380...400V drive rating, 383V nominal motor voltage
Drive operating range 325...528V @ 380...400V drive rating, 383V nominal motor voltage
Drive overcurrent trip Software current limit: 105% of motor rated to 200% of drive rated current
Drive to motor power ratio, max The drive to motor rating cannot exceed a 2:1 ratio
Dual element time delay fuse current rating 6...10A @ 400V AC, 3-phase
Efficiency 97.5% at rated A, nominal line volts
Electronic motor overload protection Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Enclosure Type IP20/NEMA/UL Type 1
Encoder voltage supply 5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC @ 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
Feedback option Future use
Feedback Options Future Use
Filter Options W/ EMC Filt & ComModeChoke
Fuse current rating 10A @ 540V DC
Ground fault trip Phase-to-ground on drive output
Heat sink thermistor Monitored by microprocessor overtemperature trip
Height, approx 336 mm
Human interface model No HIM (no blank plastic inserted)
Input current rating 5.3A @ 540V DC
Input frequency, max 400 Hz
Input phases Six-pulse, 3-phase input provides full rating for all drives, single-phase ops provides 50% of rated current
Input power rating 3.2 kVA @ 400V AC, 3-phase
Input voltage rating 400V AC, 3-phase, 50 Hz
Integrated breaking resistance false
Intermittent overload 110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Internal Communication Module No communication module
Internal dynamic brake resistors 115 ohm
Internal EMC filtering With EMC filter & common mode choke
Lifecycle Status Discontinued
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Line voltage, nom 400V @ 380...400V drive rating, 383V nominal motor voltage
Logic control ride-thru 0.25 s, drive not running
Mains frequency 50 Hz
Mains voltage 400 V
Max. output frequency 400 Hz
Max. output voltage 932 V
Motor circuit protector current rating, max 7A @ 400V AC, 3-phase
Motor voltage, nom 383V @ 380...400V drive rating, 400V nominal line voltage
Non-time delay fuse current rating 6...20A @ 400V AC, 3-phase
Number of analogue inputs 3
Number of analogue outputs 2
Number of digital inputs 6
Number of digital outputs 2
Number of phases input 3
Number of phases output 3
Operating Temperature 50 °C @ 540V DC
Output current rating 5 A, 2.2 kW normal duty, 1.5 kW heavy duty, frame 1
Output current, 1 min 5.5A @ 540V DC
Output current, 3 sec 7.5A @ 540V DC
Output current, continuous 5.0A @ 540V DC
Output frequency range 0 Hz
Output voltage range 0 to rated motor voltage
Power ride-thru 15 ms at full load
PWM frequency 4 kHz @ 540V DC
Rated power rating 2.2 kW @ 540V DC, normal duty
Relative Humidity 5...95% noncondensing
Relative symmetric net voltage tolerance 10 %
Repair Options Available Yes
S-curve time Adjustable 0.5...4.0 s
Selectable motor control Field oriented control with and without a ftdback device and permanent magnet motor control
Serial cable 1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
Shock 10 G peak for 11 ms duration (±1.0 ms)
Short circuit current, max Using recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 A
Short circuit trip Phase-to-phase on drive output
Sound level Frame 1: 59 dB @ 30 CFM fan speed
Speed control Speed regulation - without ftdback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Stop modes Multiple progmable stop modes including - RA, Coast, and Current Limit
Storage Temperature -40 °C
Sub Brand PowerFlex 700S AC Drive
Surrounding air temperature without derating NEMA/UL Type 1: 0° to 40° C (32° to 104° F)
Torque regulation Torque regulation - without ftdback: ±5%, 600 rad/sec bandwidth
User available memory base 1.5 MB (compactflash for non-volatile storage also available)
Vibration 0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
Watt loss 135 W @ 400V AC, 2.2 kW normal duty, 1.5 kW heavy duty
Weight, approx Drive: 7.03 kg
Width, approx 166.9 mm

Frequently Asked Questions

How do I get pricing for 20DC5P0A0EYNANCNK?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 20DC5P0A0EYNANCNK?

20DC5P0A0EYNANCNK is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 20DC5P0A0EYNANCNK?

Key specifications include AC input overvoltage trip: 600V AC @ 380/400V (six pulse, 3-phase); Acceleration/deceleration: Independently progmable accel and decel times adjustable from 0 to 6553.5 in 0.1 s increments; Additional configuration: Phase II DriveLogix 5730; Altitude: 1000 m (3300 ft.) maximum without derating. The full specification table on this page lists every published attribute for this part.

How quickly can 20DC5P0A0EYNANCNK ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products