Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
20BD052A3AYNAEC0NNAD
Request a Quote Email orderdesk@kkmsolutions.com for pricing and availability.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley PowerFlex 700 AC Drive 52 A 40 Hp 20B 20BD052A3AYNAEC0NNAD

Brand: Allen-Bradley SKU: 20BD052A3AYNAEC0NNAD
Ships Same Day* Worldwide Shipping
AC input overvoltage trip 570V AC @ 480V
AC input undervoltage trip 280V AC @ 480V
Acceleration/deceleration Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Actual short circuit rating Determined by AIC rating of installed fuse/circuit breaker
Altitude 1000 m (3300 ft.) maximum without derating
Analog input latency 4.8...12.4 ms @ speed signal for SVC motor control
Analog input latency, typical 6.4 ms @ speed signal for SVC motor control
Atmosphere Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Brake IGBT Brake IGBT installed
Brake Resistor No internal brake resistor
Build America, Buy America No
Bus overvoltage trip 810V DC @ 480V
Bus undervoltage shutoff/fault 305V DC @ 480V
Bus voltage, nom 648V DC @ 480V
Carrier frequency 2, 4, 8, and 10 kHz. Drive rating based on 4 kHz
Catalog string character 17 Future use
Catalog string character 18 Future use
Circuit breaker current rating, max 200A @ 480V AC, 3-phase
Control logic noise immunity Showering arc transients upto 1500V peak
Control method Sine coded PWM with progmable carrier frequency, ratings apply to all drives, the drive can be supplied as 6 pulse or 18 pulse in an engineered solution
Control options Vector control with 24V DC I/O
Current limit capability Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Custom Drive/Firmware Optional custom software 60 Hz max.
Degree of protection (IP) IP20
Degree of protection (NEMA) 1
Depth, approx IP20, NEMA/UL type 1: 200 mm
Digital input latency 9.2...16.0 ms @ start signal for SVC motor control
Digital input latency, typical 9.2 ms @ stop signal for SVC motor control
Displacement power factor (all drives) 0.98 across speed range
Documentation Manual
Drive full power range 460...528V @ 380...480V drive rating
Drive operating range 342...528V @ 380...480V drive rating
Drive overcurrent trip Instantaneous current limit: 220...300% of rated current (dependent on drive rating)
Drive to motor power ratio, max Recommended not greater than 2:1 ratio
Drive to motor power ratio, min Recommended not less than 1:2 ratio
Dual element time delay fuse current rating 60...110A @ 480V AC, 3-phase
Efficiency 97.5% at rated A, nominal line volts
Enclosure Type IP20/NEMA/UL Type 1
Encoder duty cycle 50% ±10%
Encoder quadrature 90 degrees, ±27 degrees at 25 °C (77 °F)
Encoder requirements Encoders must be line driver type, quadrature (dual channel) or pulse (single channel), 8...15V DC output (4...6V DC when jumpers are in 5V position), single-ended or differential and capable of supplying a min. of 10 mA per channel, maximum input frequen
Encoder supply 12V @ 250mA. 12V @ 10mA minimum inputs isolated with differential transmitter, 250 kHz maximum
Encoder Type Incremental, dual channel
External watts loss 492 W @ 480V @ 40Hp normal duty (IP20, NEMA/UL Type 1)
Feedback option No ftdback
Feedback Options No ftdback
Filter Options W/ EMC Filt & ComModeChoke
Frequency accuracy Digital input: within ±0.01% of set output frequency
Frequency control-speed regulation With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Fuse current rating 90A @ 650V DC
Ground fault trip Phase-to-ground on drive output
Heat sink thermistor Monitored by microprocessor overtemp trip
Height, approx IP20, NEMA/UL type 1: 517.5 mm
Human interface model LCD display full numeric keypad with progming keys
Input current rating 55.7A @ 650V DC
Input frequency tolerance 47 Hz
Input phases 3-phase input provides full rating for all drives. 1-phase ops possible on certain drives and provides 50 % of rated current. Frames 0...6: drive can be supplied as 6 pulse or 18 pulse in an engineered package.
Input power rating 39.7 kVA @ 480V AC, 3-phase
Input voltage rating 480V AC, 3-phase, 60 Hz
Integrated breaking resistance false
Intermittent overload 110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Internal Communication Module EtherNet/IP
Internal EMC filtering With EMC filter with common mode choke
Internal watts loss 117 W @ 480V @ 40Hp normal duty (IP20, NEMA/UL Type 1)
Lifecycle Status Discontinued
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Line voltage, nom 480V @ 380...480V drive rating, 460V nominal motor voltage
Logic control ride-thru 0.5 s minimum, 2 s typical
Mains frequency 60 Hz
Mains voltage 480 V
Max. output frequency 420 Hz
Motor circuit protector current rating, max 70A @ 480V AC, 3-phase
Motor overload protection Frames 0...6 vector control: powerflex 700 drives with vector control, which is identified by a C or D in position 15 of the catalog number, provide class 10 motor overload protection according to NEC article 430 and motor overtemperature protection acco
Motor voltage, nom 460V @ 380...480V drive rating, 480V nominal line voltage
Non-time delay fuse current rating 60...200A @ 480V AC, 3-phase
Number of analogue inputs 2
Number of analogue outputs 2
Number of digital inputs 6
Number of digital outputs 3
Number of phases input 3
Number of phases output 3
Operating Temperature 50 °C @ 650V DC
Output current rating 52 A, 40 Hp normal duty, 30 Hp heavy duty, frame 3
Output current rating, 1 min 60A @ 650V DC
Output current rating, 3 sec 80A @ 650V DC
Output current rating, continuous 52A @ 650V DC
Output voltage range 0 to rated motor voltage
Output voltage rating 0...460V AC @ 480V AC, 1-phase
Pollution degree 1 according to EN 61800-5-1 No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 2 according to EN 61800-5-1 Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of ops
Pollution degree 3 according to EN 61800-5-1 Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 4 according to EN 61800-5-1 The pollution generates persistent conductivity caused, for exAle, by conductive dust, rain or snow
Power ride-thru 15 ms at full load
PWM frequency 4 kHz @ 650V DC
Relative Humidity 5...95% noncondensing
Relative symmetric net voltage tolerance 10 %
Repair Options Available Yes
Selectable motor control Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Shock 15 G peak for 11 ms duration (±1.0 ms)
Short circuit rating, max 200000 A symmetrical
Short circuit trip Phase-to-phase on drive output
Sound level Frame 3: 61 dB @ 120 CFM fan velocity
Speed control-speed regulation Without ftdback (Vector Control Mode): 0.1 % of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Stop modes Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve
Storage Temperature -40 °C
Sub Brand PowerFlex 700 AC Drive
Supporting protocol for CAN true
Supporting protocol for DeviceNet true
Supporting protocol for EtherNet/IP true
Supporting protocol for LON true
Supporting protocol for Modbus true
Supporting protocol for PROFIBUS true
Supporting protocol for TCP/IP true
Surrounding air temperature IP20, NEMA/UL type 1 (with top label): 0...50 °C (0...122 °F) @ frames 5…6, most ratings
Surrounding environment pollution degree All enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL Type 12, is required for pollution degree 3 and 4
Torque regulation Without ftdback: ±5 %, 600 rad/sec bandwidth
Total watts loss 610 W @ 480V @ 40Hp normal duty (IP20, NEMA/UL Type 1)
Vibration 0.152 mm (0.006 in) displacement, 1 G peak
Weight, approx IP20, NEMA/UL type 1: 22.68 kg (drive and packaging weight)
Width, approx IP20, NEMA/UL type 1: 222 mm
With control element true

Frequently Asked Questions

How do I get pricing for 20BD052A3AYNAEC0NNAD?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 20BD052A3AYNAEC0NNAD?

20BD052A3AYNAEC0NNAD is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 20BD052A3AYNAEC0NNAD?

Key specifications include AC input overvoltage trip: 570V AC @ 480V; AC input undervoltage trip: 280V AC @ 480V; Acceleration/deceleration: Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments; Actual short circuit rating: Determined by AIC rating of installed fuse/circuit breaker. The full specification table on this page lists every published attribute for this part.

How quickly can 20BD052A3AYNAEC0NNAD ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products