Allen-Bradley PowerFlex 70 AC Drive 4.2 A at 1 Hp 20A 20AB4P2C3AYNNNC1

Brand: Allen-Bradley SKU: 20AB4P2C3AYNNNC1
Ships Same Day* Worldwide Shipping
AC input overvoltage trip 285V AC @ 240V
AC input undervoltage trip 138V AC @ 240V
Acceleration/deceleration Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Altitude 1000 m (3300 ft.) maximum without derating
Application in domestic- and commercial area permitted true
Application in industrial area permitted true
Atmosphere Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Brake IGBT Brake IGBT installed
Brake Resistor Without drive mounted brake resistor
Build America, Buy America No
Bus overvoltage trip 405V DC @ 240V
Bus undervoltage fault level 160V DC @ 240V
Bus undervoltage output shutoff 153V DC @ 240V
Bus voltage, nom 324V DC @ 240V
Carrier frequency Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz
Circuit breaker current rating, max 15A @ 240V AC, 3-phase
Control Enhanced Control with 24V I/O
Control logic noise immunity Showering arc transients upto 1500V peak
Control method Sine coded PWM with progmable carrier frequency. Ratings apply to all drives
Control options Enhanced control with 24V I/O
Cooling fan operation Frames B, D, and E: fan operates when power is applied and in run condition
Current limit capability Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Degree of protection (IP) IP66
Degree of protection (NEMA) 4X
Depth, approx IP20, NEMA/UL Type 1: 179.8 mm
Displacement power factor (all drives) 0.98 across speed range
Documentation Manual
Drive full power range 230...264V @ 200...240V drive rating, 230V nominal motor voltage
Drive operating range 180...264V @ 200...240V drive rating, 230V nominal motor voltage
Drive overcurrent trip Software current limit: 20...160% of rated current
Drive to motor power ratio, max Recommended not greater than 2:1 ratio
Drive to motor power ratio, min Recommended not less than 1:2 ratio
Dual element time delay fuse current rating 6...9A @ 240V AC, 3-phase
Efficiency 97.5% at rated A, nominal line volts
Enclosure Type Wall/machine mount-IP66/NEMA Type 4X/12 (indoor use)
Encoder duty cycle 50% ±10%
Encoder quadrature 90° ±27°
Encoder supply 5V/12V configurable ±5%
Encoder Type Incremental, dual channel
External watts loss 30.7 W @ 240V @ 1.0Hp normal duty
Feedback option Standard encoder, enhanced control
Filter Options W/O EMC Filt & ComModeChoke
Frequency accuracy Digital input: within ±0.01% of set output frequency
Frequency control-speed regulation With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Ground fault trip Phase-to-ground on drive output
Heat sink thermistor Monitored by microprocessor overtemp trip
Height, approx IP20, NEMA/UL Type 1: 225.7 mm
Human interface model LCD display, full numeric keypad
Input current rating 5.6A @ 208V AC, 3-phase
Input frequency tolerance 47 Hz
Input phases Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current
Input power rating 2 kVA @ 240V AC, 3-phase
Integrated breaking resistance false
Intermittent overload 110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Internal Communication Module No communication module
Internal dynamic brake resistors 62 ohm
Internal EMC filtering Without EMC filter & common mode choke
Internal watts loss 20.5 W @ 240V @ 1.0Hp normal duty
Lifecycle Status End_of_life
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Line voltage, nom 240V @ 200...240V drive rating, 230V nominal motor voltage
Logic control ride-thru 0.5 s minimum, 2 s typical
Mains frequency 60 Hz
Mains voltage 240 V
Motor circuit protector current rating, max 7A @ 240V AC, 3-phase
Motor overload protection Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Motor voltage, nom 230V @ 200...240V drive rating, 240V nominal line voltage
Non-time delay fuse current rating 6...15A @ 240V AC, 3-phase
Number of analogue inputs 2
Number of analogue outputs 1
Number of digital inputs 6
Number of digital outputs 2
Number of HW-interfaces RS-232 2
Number of HW-interfaces RS-485 2
Number of HW-interfaces USB 2
Number of phases input 3
Number of phases output 3
Output current rating 4.8 A, 0.75 Hp normal duty, frame A (208V @ 60Hz input)
Output current rating, 1 min 5.5A @ 208V AC, 3-phase
Output current rating, 3 sec 7.4A @ 208V AC, 3-phase
Output current rating, continuous 4.8A @ 208V AC, 3-phase
Output frequency range Standard control: 0...400 Hz, enhanced control: 0...500 Hz
Output voltage range 0 to rated motor voltage
Pollution degree 1 according to EN 61800-5-1 No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 2 according to EN 61800-5-1 Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of ops
Pollution degree 3 according to EN 61800-5-1 Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 4 according to EN 61800-5-1 The pollution generates persistent conductivity caused, for exAle, by conductive dust, rain or snow
Power ride-thru 15 ms at full load
Relative Humidity 5...95% noncondensing
Relative symmetric net voltage tolerance 10 %
Repair Options Available Yes
Selectable motor control Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Shock 15 G peak for 11 ms duration (±1.0 ms)
Short circuit current rating, max Maximum short circuit current rating to match specified fuse/circuit breaker capability
Short circuit rating, max 200000 A symmetrical
Short circuit trip Phase-to-phase on drive output
Speed control-speed regulation Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth
Stop modes Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve
Storage Temperature -40 °C
Sub Brand PowerFlex 70 AC Drive
Supporting protocol for CAN true
Supporting protocol for DeviceNet true
Supporting protocol for EtherNet/IP true
Supporting protocol for Modbus true
Supporting protocol for PROFIBUS true
Supporting protocol for TCP/IP true
Surrounding air temperature, max IP66, NEMA/UL Type 4X/12(indoor): 0...40 °C (32...104 °F) without derating
Surrounding environment pollution degree All enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL type 12, is required for pollution degree 3 and 4
Torque regulation Without ftdback +/-10%, with ftdback +/-5%
Total watts loss 51.2 W @ 240V @ 1.0Hp normal duty
Vibration 0.152 mm (0.006 in) displacement, 1 G peak
Voltage tolerance -10 %
Weight, approx IP20, NEMA/UL Type 1: 2.71 kg
Width, approx IP20, NEMA/UL Type 1: 122.4 mm
With control element true

Frequently Asked Questions

How do I get pricing for 20AB4P2C3AYNNNC1?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 20AB4P2C3AYNNNC1?

20AB4P2C3AYNNNC1 is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 20AB4P2C3AYNNNC1?

Key specifications include AC input overvoltage trip: 285V AC @ 240V; AC input undervoltage trip: 138V AC @ 240V; Acceleration/deceleration: Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments; Altitude: 1000 m (3300 ft.) maximum without derating. The full specification table on this page lists every published attribute for this part.

How quickly can 20AB4P2C3AYNNNC1 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products