Allen-Bradley IEC Miniature Reversing Contactor 104-K09KA02
Allen-Bradley 104-K09KA02 - industrial components - Function: Reversing contactor; Contacts: 3 power poles with internal NC auxiliary contact; Ambient temperature: Storage: -55...80 (-67...176).
The 104-K09KA02 from Allen-Bradley is listed under industrial components in our catalog. The manufacturer's published data for this part number specifies Function: Reversing contactor and Contacts: 3 power poles with internal NC auxiliary contact.
The specification set recorded for this part number covers Ambient temperature: Storage: -55...80 (-67...176); Lifecycle Status: Active; Build America, Buy America: No; Repair Options Available: No; Sub Brand: IEC; Degree of protection (IP): IP2X; Rated control supply voltage at AC 50 Hz: 240 V; Rated control supply voltage at AC 60 Hz: 240 V; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: AC; Recommended torque: 10.6 in-lb; Switching frequency, max: 250 ops/h, AC-4 (approximately 200000 ops). See the Specifications tab on this page for the full technical table.
| Altitude of installation site, max | 2000 m (NN), per IEC 60947-4 |
|---|---|
| Ambient temperature | Storage: -55...80 (-67...176) |
| Auxiliary contact configuration | 1 NC |
| Auxiliary contacts | IP2X |
| Build America, Buy America | No |
| Coil consumption, hold-in | 5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil consumption, pick-up | 35VA @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil insulation class | Class F per IEC 60085, Class 105 insulation system per UL 508 |
| Coil operating limits, dropout | (0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil operating limits, pick-up | (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil operating time | 15...40 ms, closing delay @ AC |
| Coil voltage | 240V 50/60 Hz |
| Conductor cross section per UL/CSA | 18 |
| Conductor cross-section | 0.75...2.5 mm², 2 conductors @ main contact |
| Contactor size | 9 A |
| Contacts | 3 power poles with internal NC auxiliary contact |
| Current (Ie), max | 12 A |
| Current rating | 5 A |
| Degree of protection (IP) | IP2X |
| DIN fuses (gG, gL) current rating | Type 2 (per IEC 60947-4-1): 20A @ 400V, 50 kA available fault current |
| Features | Mini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materials |
| Function | Reversing contactor |
| Function or layout | Nothing specified |
| General purpose current (enclosed) | 15 A per UL/CSA |
| Lifecycle Status | Active |
| Lifespan | Mechanical DC control: 15000000 ops |
| Main current circuit resistance | 2.2 mohm |
| Optional accessories | Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks |
| Optional overload relays | Bimetallic |
| Power dissipation by all circuits at Ie AC-3/400V | 0.9 W |
| Rated coil frequency | AC 50/60 Hz, DC |
| Rated control supply voltage at AC 50 Hz | 240 V |
| Rated control supply voltage at AC 60 Hz | 240 V |
| Rated control supply voltage at DC | 0 V |
| Rated current (enclosed) | 9.8A @ 115V, 1-phase per UL/CSA |
| Rated filament current | 9A @ 230/240V, AC-5b |
| Rated impulse withstand voltage (Uimp) | 6 kV |
| Rated isolation voltage (Ui) | 690V per IEC |
| Rated operational current (Ie) | 8.9A @ 690V, Star-Delta starting (50 Hz) |
| Rated operational power (Pe) | 8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C |
| Rated power (enclosed) | 5Hp @ 575V, 3-phase per UL/CSA |
| Rated voltage (Ue) | 690V @ AC, 50/60 Hz |
| Rating for switching AC motors | 3-poles: 4 kW @ 690V (AC-2, AC-3, AC-4), 3-phase (50 Hz) |
| Recommended torque | 10.6 in-lb |
| Repair Options Available | No |
| Shock resistance | IEC 60068-2 |
| Short time withstand (Icw) | 96A @ 10s, 60 °C |
| Sub Brand | IEC |
| Switching frequency, max | 250 ops/h, AC-4 (approximately 200000 ops) |
| Switching of DC loads | 3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
| Switching of hermetically sealed cooling compressor motors | 18A @ 400V, AC-8a (manual reset of overload release (50 Hz)) |
| Switching of lamps | Gas discharge lA, open: 18A @ 40°C, AC-5a |
| Switching of low inductive loads in home appliances | 20A @ 400V, AC-7a per IEC 61095 (50 Hz) |
| Switching of motor load for home appliances | 11A @ 400V, AC-7b (50 Hz) |
| Switching of power transformers | Apparent power: 4 kVA @ 690V, AC-6a @ 50Hz (n = 30) |
| Terminal Type | Screw terminals |
| Total power dissipation | DC control: 3.5 W @ 400V, AC-3, Ie |
| Type of electrical connection of main circuit | Screw connection |
| UL class CC and CSA HRCI-MISC fuses rating | 30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| UL class J and CSA HRCI-J fuses rating | 30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| UL class K5 and RK5 fuses rating | 40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| Vibration resistance | IEC 60068-2 |
| Voltage type for actuating | AC |
Frequently Asked Questions
How do I get pricing for 104-K09KA02?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 104-K09KA02?
104-K09KA02 is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 104-K09KA02?
Key specifications include Altitude of installation site, max: 2000 m (NN), per IEC 60947-4; Ambient temperature: Storage: -55...80 (-67...176); Auxiliary contact configuration: 1 NC; Auxiliary contacts: IP2X. The full specification table on this page lists every published attribute for this part.
How quickly can 104-K09KA02 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Allen-Bradley Allen-Bradley IEC Reversing Contactor 104-K12WJ02-X14
Allen-Bradley Allen-Bradley IEC 65 A Reversing Contactor 104-E65KY22
Allen-Bradley Allen-Bradley IEC Enclosed Reversing Starter 105-C09AA-A2G-3-4RG-6P
Allen-Bradley Allen-Bradley IEC 65 A Reversing Contactor 104-E65KJ22
Allen-Bradley Allen-Bradley IEC Enclosed Reversing Starter 105-C09AA-A2G-3-4RW
Allen-Bradley
Industrial & MRO Parts