Allen-Bradley IEC 26 A Safety Contactor 100S-E26KD422C
Allen-Bradley 100S-E26KD422C - IEC Safety Contactors - Width: Approx 101 mm mm; Length: Approx 45 mm ft; Height: Approx 86 mm mm.
The 100S-E26KD422C from Allen-Bradley is listed under IEC Safety Contactors in our catalog. The manufacturer's published data for this part number specifies Width: Approx 101 mm mm and Length: Approx 45 mm ft.
Key manufacturer data on file for this item includes Height: Approx 86 mm mm; Function: Non-reversing safety contactor; Weight: AC/DC (electronic): 0.48 kg (1.06 lbs.); Ambient temperature: Storage: -60...80 °C (-76...176 °F); Lifecycle Status: Active; Build America, Buy America: No; Repair Options Available: No; Rated control supply voltage at AC 50 Hz: 100 V; Rated control supply voltage at AC 60 Hz: 100 V; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: AC/DC; Switching frequency, max: 600 ops/hr, AC-1. The complete technical table is shown in the Specifications tab on this page.
| Altitude, max | 3000 m of installation site |
|---|---|
| Ambient temperature | Storage: -60...80 °C (-76...176 °F) |
| Build America, Buy America | No |
| Climatic withstand | Category B according to IEC 60947-1, annex Q |
| DIN fuses (gG) current rating | Type 2 (per IEC 60947-4-1): 62A @ 400V, 100 kA available fault current |
| Electromagnetic compatibility | IEC 60947-1 - Environment A and B (100-E09...E38 only.) |
| Features | Mirror contact performance on auxiliary contacts, Red N.C. low-power auxiliary contacts used for ftdback circuit, SUVA third-party certification, AC/ DC operating coils, Mirror contact symbol on front |
| FLA | 45A @ 600V, 3-phase per UL/CSA HVAC applications |
| Function | Non-reversing safety contactor |
| General purpose current (enclosed) | 24A @ 600V per UL/CSA |
| Height | Approx 86 mm mm |
| Length | Approx 45 mm ft |
| Lifecycle Status | Active |
| LRA | 270 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications |
| Main current circuit resistance | 0.29 mΩ |
| MCCB current rating | Type 2 (per IEC 60947-4-1): 56A @ 400V, 70 kA available fault current |
| Number of auxiliary contacts as normally closed contact | 2 |
| Number of auxiliary contacts as normally open contact | 2 |
| Number of normally closed contacts as main contact | 0.000000 |
| Number of normally open contacts as main contact | 4 |
| Operating limits, dropout | (≤0.60) x Us @ DC control |
| Operating limits, pick-up | (0.85...1.1) x Us @ 50/60 Hz |
| Operating time, closing delay | 40 ms |
| Operating time, opening delay | 11 ms |
| Optional accessories | Side-mount auxiliary contacts, Mechanical interlocks |
| Power dissipation | 2.4 W per pole at Ie, AC-1, 400V |
| Protection class | Contactor main contact: IP2X |
| Rated control supply voltage at AC 50 Hz | 100 V |
| Rated control supply voltage at AC 60 Hz | 100 V |
| Rated control supply voltage at DC | 100 V |
| Rated impulse voltage withstand (Uimp) | 6 kV |
| Rated isolation voltage (Ui) | 690V per IEC |
| Rated operational current (Ie) | 4-poles: 45A @ 40°C, AC-1 (690V) |
| Rated operational current and power | 9.6A @ 230V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty |
| Rated operational current and power (enclosed) | 7.5 Hp @ 220-240V, 3-phase per UL/CSA |
| Rated operational power (Pe) | 6.5 kW @ 220-240V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F) |
| Rated voltage (Ue) | 24V @ 48V, 110V @ 220V, 440V DC |
| Rating for switching AC motors | 3-poles: 7.5Hp @ 230V, AC-2, AC-3 (60 Hz) |
| Repair Options Available | No |
| Shock resistance | IEC 60068-2-27 |
| Short time withstand (Icw) | 3-pole: 700A @ 1s (40 °C) |
| Standard coil, hold-in | 2.2VA/2 W @ 100...250V AC/DC |
| Standard coil, pick-up | 50VA/50 W @ 100...250V AC/DC |
| Switching frequency, max | 600 ops/hr, AC-1 |
| Switching of DC loads | 4-poles in series: 45A @ 220V (non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
| Switching of lighting loads | Tungsten lA: 45A @ 600V, 3-phase (break all lines) per UL/CSA |
| Switching of power transformers | Apparent power: 9 kVA @ 200V @ 60Hz (n = 30) |
| Total power dissipation | 4.7 W at Ie, AC-3, 400V, AC/DC control (120-250V) |
| Type of electrical connection of main circuit | Screw connection |
| UL class J and CSA HRCI-J fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 100 kA available fault current |
| UL class RK5 fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current |
| UL inverse-time circuit breaker | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 100A @ 600V, 25 kA available fault current |
| Vibration resistance | IEC 60068-2-6 |
| Voltage type for actuating | AC/DC |
| Weight | AC/DC (electronic): 0.48 kg (1.06 lbs.) |
| Width | Approx 101 mm mm |
Frequently Asked Questions
How do I get pricing for 100S-E26KD422C?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 100S-E26KD422C?
100S-E26KD422C is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of 100S-E26KD422C?
Key specifications include Altitude, max: 3000 m of installation site; Ambient temperature: Storage: -60...80 °C (-76...176 °F); Build America, Buy America: No; Climatic withstand: Category B according to IEC 60947-1, annex Q. The full specification table on this page lists every published attribute for this part.
How quickly can 100S-E26KD422C ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Allen-Bradley Allen-Bradley IEC 26 A Safety Contactor 100S-E26EJ22C
Allen-Bradley Allen-Bradley IEC 26 A Safety Contactor 100S-E26QJ13C
Allen-Bradley Allen-Bradley IEC 305 A Safety Contactor 100S-E305ED12C
Allen-Bradley Allen-Bradley IEC 265 A Safety Contactor 100S-E265KD12C
Allen-Bradley Allen-Bradley IEC 30 A Safety Contactor 100S-E30KD31C
Allen-Bradley
Industrial & MRO Parts